Gas power plant in Guangxi Zhuangzu Zizhiqu, China. Approximate location 25.2107, 110.1806.

GasGuangxi Zhuangzu ZizhiquChinaCCGT · HRSGGE Vernova: 6F.01CO₂ modelled

Huaneng Guilin Distributed Gas power station is a 189 MW gas power station in Guangxi Zhuangzu Zizhiqu, China. It is operated by Huaneng Guilin Gas Distributed Energy Co Ltd. Based on its capacity (estimated), it can supply roughly 213k homes (estimated). It ranks #2207 of 6,685 China power plants by installed capacity. Commissioned in 2017, it is around 9 years old — relatively modern. Its modelled annual emissions are 350,620 t CO₂/yr (Climate TRACE), equivalent to about 82k cars driven for a year. In context, gas supplies about 3.2% of China's electricity; the national grid averages 525 gCO₂/kWh (41.7% low-carbon) (2025).

189Source-backed capacity
3HRSG unit(s)
212,868homes powered (est.)
350,620t CO₂ / yr (Climate TRACE)
2017commissioned (~9 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CT-3302.

Data status

Known data

FacilityHuaneng Guilin Distributed Gas power station Climate TRACE
CountryChina · Guangxi Zhuangzu Zizhiqu Climate TRACE
Coordinates25.2107, 110.1806 Climate TRACE
FuelGas Climate TRACE
MW installed capacity189 MW Climate TRACE source record; scope not independently normalised
OwnerHuaneng Guilin Gas Distributed Energy Co Ltd Climate TRACE
Commissioned2017 Climate TRACE
TechnologyCCGT · GE Vernova: 6F.01 · HRSG Climate TRACE

Modelled source data

CO₂ emissions350,620 t CO₂/yr modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#2207 of 6685 calculated
Fuel-specific rank in country#360 of 595 calculated
Capacity vs country/fuel peers0.67× · 284 MW median · 595 peers calculated
Homes-powered equivalent212,868 calculated
Climate19.4°C · HDD 933 derived from coordinates
Environmental severityC3 · 39/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000405733); fuel: Climate TRACE source-record fuel

In context: how this plant compares

At 189 MW, Huaneng Guilin Distributed Gas power station is below the median gas plant in China (284 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG); GE Vernova: 6F.01. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~350,620 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

82kpassenger cars driven for a year
46khomes' yearly energy use
5.8 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Capacity vs largest gas plants in China

Datang Wushi power station: 3,900 MW4kDatang Wus…Jingneng Beihai power station: 3,200 MW3kJingneng B…Jiangsu Rudong Combined Cycle Gas Turbine power station: 3,120 MW3kJiangsu Ru…Wenzhou Dongtou power station: 3,120 MW3kWenzhou Do…Guanghai Bay power station: 2,900 MW3kGuanghai B…Chongqing Changshou power station: 2,800 MW3kChongqing …Chongqing Tongliang power station: 2,800 MW3kChongqing …Sichuan Deyang Zhongjiang power station: 2,800 MW3kSichuan De…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Huaneng Guilin Gas Distributed Energy Co Ltd.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 25.2°N — which shapes how much energy it can produce and how its output varies through the year.

19.4°Cannual mean temp
933heating degree-days (base 18°C)
1,446cooling degree-days (base 18°C)
172 melevation

Monthly mean temperature

J: 8 °CJF: 10 °CFM: 14 °CMA: 19 °CAM: 24 °CMJ: 27 °CJJ: 28 °CJA: 28 °CAS: 26 °CSO: 21 °CON: 16 °CND: 11 °CD28 °C

Heating degree-days here run 62% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 26/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~3% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
39/100environmental-severity index
19.9°Cseasonal temperature swing
453 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #360 largest gas power plant of 595 in China by capacity.

China has 595 gas power plants in this dataset, together about 333,508 MW of capacity.

Nearby power plants

Location

Coordinates 25.2107, 110.1806 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Huaneng Guilin Distributed Gas power station?

Huaneng Guilin Distributed Gas power station is a 189 MW source-record gas power plant in Guangxi Zhuangzu Zizhiqu, China, commissioned in 2017.

How many homes can Huaneng Guilin Distributed Gas power station power?

Its output is enough to supply roughly 212,868 homes (estimated).

Who operates Huaneng Guilin Distributed Gas power station?

Huaneng Guilin Distributed Gas power station is operated by Huaneng Guilin Gas Distributed Energy Co Ltd.

How much CO₂ does Huaneng Guilin Distributed Gas power station emit?

Huaneng Guilin Distributed Gas power station has modelled emissions of about 350,620 tonnes of CO₂ per year (Climate TRACE).

Built from open public data; no personal information. Operate this site? Request a correction or removal.