Home / Europe / Spain / Granadilla power station

Granadilla power station

Oil power plant in Tenerife, Spain. Approximate location 28.12218, -16.573048.

OilTenerifeSpainCCGT · HRSGCO₂ measured

Granadilla power station is a 749 MW oil power station in Tenerife, Spain. It is operated by Endesa SA [100%]. Based on its capacity (estimated), it can supply roughly 562k homes (estimated). It ranks #45 of 899 Spain power plants by installed capacity. Commissioned in 1990, it is around 36 years old — long-established. Its annual emissions of 1,901,268 t CO₂/yr (EU ETS verified (EUTL 2023)) are equivalent to about 443k cars driven for a year. In context, oil supplies about 3.5% of Spain's electricity; the national grid averages 154 gCO₂/kWh (74.6% low-carbon) (2025).

749MW installed capacity
2HRSG unit(s)
562,392homes powered (est.)
1,901,268t CO₂ / yr (EU ETS verified (EUTL 2023))
1990commissioned (~36 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_granadilla_spain.

Data status

Known data

FacilityGranadilla power station GEM-GOGPT
CountrySpain · Tenerife GEM-GOGPT
Coordinates28.12218, -16.573048 GEM-GOGPT
FuelOil GEM-GOGPT
MW installed capacity749 MW GEM · 2026 · L100000408754; operating plant capacity
OwnerEndesa SA [100%] GEM-GOGPT
Commissioned1990 GEM-GOGPT
TechnologyCCGT · HRSG GEM-GOGPT
CO₂ emissions1,901,268 t CO₂·a⁻¹ measured · EU ETS verified (EUTL 2023)

Calculated from dataset

Capacity rank in country#45 / 899 calculated
Fuel-specific rank in country#2 / 33 calculated
Capacity vs country/fuel peers11.13× · 67.3 MW · n=33 calculated
Homes-powered equivalent562,392 calculated
Environmental severityC5 · 42/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000408754; fuel: GEM GOGPT

In context: how this plant compares

At 749 MW, Granadilla power station is well above the median oil plant in Spain (67.3 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

1,901,268 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

443kpassenger cars driven for a year
248khomes' yearly energy use
32 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per EU ETS verified (EUTL 2023) (measured for US EPA/EU ETS, modelled for Climate TRACE).

Capacity vs largest oil plants in Spain

CT SANTURCE 2: 897 MW897CT SANTURC…Granadilla power station: 749 MW749Granadilla…BARRANCO DE TIRAJANA 7 VAPOR 3 (CC1): 697 MW697BARRANCO D…GRANADILLA 1 GAS 1: 693 MW693GRANADILLA…SON REUS 3 TURBINA DE GAS N 3: 564 MW564SON REUS 3…CT ESCOMBRERAS 5: 537 MW537CT ESCOMBR…JINAMAR 10 GAS 2: 234 MW234JINAMAR 10…MAHON 10 BURMEISTER N 2: 195 MW195MAHON 10 …

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Endesa SA [100%].

Climate zone & how it works

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a warm-summer Mediterranean climate (Köppen Csb) — Northern Hemisphere, latitude 28.1°N — which shapes how much energy it can produce and how its output varies through the year.

~14°Ctypical annual mean
~21°Ctypical warm-season mean
Warm-summer mediterranean: hot summers and mild winters

Climate zone & typical temperatures: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
42/100environmental-severity index
6.8°Cseasonal temperature swing
18 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest oil power plant of 33 in Spain by capacity.

Spain has 33 oil power plants in this dataset, together about 6,078 MW of capacity.

Nearby power plants

Location

Coordinates 28.12218, -16.573048 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Granadilla power station?

Granadilla power station is a 749 MW oil power plant in Tenerife, Spain, commissioned in 1990.

How many homes can Granadilla power station power?

Its output is enough to supply roughly 562,392 homes (estimated).

Who operates Granadilla power station?

Granadilla power station is operated by Endesa SA [100%].

How much CO₂ does Granadilla power station emit?

Granadilla power station has measured emissions of about 1,901,268 tonnes of CO₂ per year (EU ETS verified (EUTL 2023)).

Built from open public data; no personal information. Operate this site? Request a correction or removal.