Home / Europe / Italy / E.ON C.TE LIVORNO FERRARIS

E.ON C.TE LIVORNO FERRARIS — Italy

Gas power plant in Piedmont, Italy. Approximate location 45.2372, 8.1932.

GasPiedmontItalyCO₂ modelled

E.ON C.TE LIVORNO FERRARIS is a 804 MW gas power station in Piedmont, Italy. It is operated by EP Produzione Centrale Livorno Ferraris SpA. Based on reported annual generation of 4,386 GWh, it can supply roughly 1.3 million homes. It ranks #41 of 489 Italy power plants by installed capacity. Its modelled annual emissions are 1,493,925 t CO₂/yr (Climate TRACE), equivalent to about 348k cars driven for a year. In context, gas supplies about 47.2% of Italy's electricity; the national grid averages 285 gCO₂/kWh (48.8% low-carbon) (2025).

804MW installed capacity
4,386GWh reported / yr
1,253,142homes powered
1,493,925t CO₂ / yr (Climate TRACE)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1002876.

Data status

Known data

FacilityE.ON C.TE LIVORNO FERRARIS WRI
CountryItaly · Piedmont WRI
Coordinates45.2372, 8.1932 WRI
FuelGas WRI
MW installed capacity804 MW WRI GPPD; source record
OwnerEP Produzione Centrale Livorno Ferraris SpA WRI
GWh reported / yr4,386 GWh·a⁻¹ WRI

Modelled source data

CO₂ emissions1,493,925 t CO₂·a⁻¹ modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#41 / 489 calculated
Fuel-specific rank in country#24 / 118 calculated
Capacity vs country/fuel peers2.48× · 324 MW · n=118 calculated
Homes-powered equivalent1,253,142 calculated from reported generation
Climate12.3°C · HDD 2,384 derived from coordinates
Environmental severityC3 · 35/100 derived from coordinates

Not available

CommissionedNot available not in dataset
TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Capacity and fuel are the upstream open-dataset record, not yet matched to a 2026 registry or GEM entry.

capacity: WRI GPPD; fuel: WRI GPPD

In context: how this plant compares

At 804 MW, E.ON C.TE LIVORNO FERRARIS is well above the median gas plant in Italy (324 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~1,493,925 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

27kmillion cubic feet of natural gas burned
348kgasoline cars driven for a year
446wind turbines running for a year
3.0%of the CO₂ from all Italy power plants with an emissions figure in PowerAtlas

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Key facts

Load factor
62%, from 4,386 GWh of reported generation; the median for 51 gas plants in Italy that report generation is 24%
Generation trend
2,391 GWh in 2015 and 4,386 GWh in 2017 (+83%)
Highest and lowest year
2017: 4,386 GWh; 2015: 2,391 GWh
Share of Italy gas capacity
1.5% of 53,570 MW across 118 plants in this dataset

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2015: 2,391 GWh20152016: 2,801 GWh20162017: 4,386 GWh20174k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by EP Produzione Centrale Livorno Ferraris SpA.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 45.2°N — which shapes how much energy it can produce and how its output varies through the year.

12.3°Cannual mean temp
2,384heating degree-days (base 18°C)
330cooling degree-days (base 18°C)
223 melevation

Monthly mean temperature

J: 2 °CJF: 4 °CFM: 8 °CMA: 12 °CAM: 16 °CMJ: 20 °CJJ: 23 °CJA: 22 °CAS: 18 °CSO: 13 °CON: 7 °CND: 3 °CD23 °C

Heating degree-days here run 3% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 49/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
35/100environmental-severity index
20.2°Cseasonal temperature swing
104 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #24 largest gas power plant of 118 in Italy by capacity.

Italy has 118 gas power plants in this dataset, together about 53,570 MW of capacity.

Nearby power plants

Location

Coordinates 45.2372, 8.1932 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is E.ON C.TE LIVORNO FERRARIS?

E.ON C.TE LIVORNO FERRARIS is a 804 MW gas power plant in Piedmont, Italy.

How much electricity does E.ON C.TE LIVORNO FERRARIS generate?

E.ON C.TE LIVORNO FERRARIS generates about 4,386 GWh of electricity per year.

Who operates E.ON C.TE LIVORNO FERRARIS?

E.ON C.TE LIVORNO FERRARIS is operated by EP Produzione Centrale Livorno Ferraris SpA.

How much CO₂ does E.ON C.TE LIVORNO FERRARIS emit?

E.ON C.TE LIVORNO FERRARIS has modelled emissions of about 1,493,925 tonnes of CO₂ per year (Climate TRACE).