Home / Asia / South Korea / Dangjin Combined Cycle power station

Dangjin Combined Cycle power station

Gas power plant in Chungcheongnam-do, South Korea. Approximate location 36.959, 126.7825.

GasChungcheongnam-doSouth KoreaCCGT · HRSGCO₂ modelled

Dangjin Combined Cycle power station is a 2,406 MW gas power station in Chungcheongnam-do, South Korea. It is operated by GS EPS Co Ltd. Based on its capacity (estimated), it can supply roughly 2.7 million homes (estimated). It ranks #16 of 216 South Korea power plants by installed capacity. Commissioned in 2001, it is around 25 years old — relatively modern. Its modelled annual emissions are 3,255,100 t CO₂/yr (Climate TRACE), equivalent to about 759k cars driven for a year. In context, gas supplies about 27.9% of South Korea's electricity; the national grid averages 417 gCO₂/kWh (40.0% low-carbon) (2025).

2,406Source-backed capacity
4HRSG unit(s)
2,709,843homes powered (est.)
3,255,100t CO₂ / yr (Climate TRACE)
2001commissioned (~25 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CT-5409.

Data status

Known data

FacilityDangjin Combined Cycle power station Climate TRACE
CountrySouth Korea · Chungcheongnam-do Climate TRACE
Coordinates36.959, 126.7825 Climate TRACE
FuelGas Climate TRACE
MW installed capacity2,406 MW Climate TRACE source record; scope not independently normalised
OwnerGS EPS Co Ltd Climate TRACE
Commissioned2001 Climate TRACE
TechnologyCCGT · HRSG Climate TRACE

Modelled source data

CO₂ emissions3,255,100 t CO₂/yr modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#16 of 216 calculated
Fuel-specific rank in country#2 of 77 calculated
Capacity vs country/fuel peers4.67× · 515 MW median · 77 peers calculated
Homes-powered equivalent2,709,843 calculated
Climate11.6°C · HDD 2,890 derived from coordinates
Environmental severityC3 · 40/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000401359); fuel: Climate TRACE source-record fuel

In context: how this plant compares

At 2,406 MW, Dangjin Combined Cycle power station is well above the median gas plant in South Korea (515 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~3,255,100 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

759kpassenger cars driven for a year
425khomes' yearly energy use
54 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Capacity vs largest gas plants in South Korea

Incheon: 3,052 MW3kIncheonDangjin Combined Cycle power station: 2,406 MW2kDangjin Co…Samchonpo power station: 2,120 MW2kSamchonpo …KOMIPO Incheon: 1,960 MW2kKOMIPO Inc…Boryeong (CC): 1,800 MW2kBoryeong (…Busan (pusan): 1,800 MW2kBusan (pus…Seoincheon: 1,800 MW2kSeoincheonShinincheon: 1,800 MW2kShinincheon

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by GS EPS Co Ltd.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 37.0°N — which shapes how much energy it can produce and how its output varies through the year.

11.6°Cannual mean temp
2,890heating degree-days (base 18°C)
597cooling degree-days (base 18°C)
31 melevation

Monthly mean temperature

J: -3 °CJF: -1 °CFM: 4 °CMA: 11 °CAM: 17 °CMJ: 21 °CJJ: 25 °CJA: 25 °CAS: 20 °CSO: 14 °CON: 6 °CND: 0 °CD25 °C

Heating degree-days here run 18% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 59/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
40/100environmental-severity index
28.2°Cseasonal temperature swing
56 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest gas power plant of 77 in South Korea by capacity.

South Korea has 77 gas power plants in this dataset, together about 58,006 MW of capacity.

Nearby power plants

Location

Coordinates 36.959, 126.7825 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Dangjin Combined Cycle power station?

Dangjin Combined Cycle power station is a 2,406 MW source-record gas power plant in Chungcheongnam-do, South Korea, commissioned in 2001.

How many homes can Dangjin Combined Cycle power station power?

Its output is enough to supply roughly 2,709,843 homes (estimated).

Who operates Dangjin Combined Cycle power station?

Dangjin Combined Cycle power station is operated by GS EPS Co Ltd.

How much CO₂ does Dangjin Combined Cycle power station emit?

Dangjin Combined Cycle power station has modelled emissions of about 3,255,100 tonnes of CO₂ per year (Climate TRACE).