Home / Europe / Italy / Colleferro

Colleferro

Solar power plant in Latium, Italy. Approximate location 41.758, 13.013.

SolarLatiumItalyCO₂ reported

Colleferro is a 18 MW solar power plant in Latium, Italy. Based on its capacity (estimated), it can supply roughly 7,743 homes (estimated). It ranks #227 of 441 Italy power plants by installed capacity. Its measured emissions of 29,208 t CO₂/yr (EU ETS) are equivalent to about 6,808 cars driven for a year. In context, solar supplies about 16.9% of Italy's electricity; the national grid averages 285 gCO₂/kWh (48.8% low-carbon) (2025).

18MW installed capacity
7,743homes powered (est.)
29,208t CO₂ / yr (EU ETS)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WKS0062404.

29,208 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

6,808passenger cars driven for a year
3,809homes' yearly energy use
486,800tree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions reported to EU ETS.

Capacity vs largest solar plants in Italy

EMMEZETA SOLAR PARK ROVIGO: 65 MW65EMMEZETA S…MdC Octopus: 57 MW57MdC OctopusSerenissima: 48 MW48SerenissimaMdC III+IV: 44 MW44MdC III+IVCellino San Marco: 43 MW43Cellino Sa…Vega Apulia: 40 MW40Vega ApuliaSant' Alberto: 35 MW35Sant' Albe…Fiumesanto: 33 MW33Fiumesanto

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This solar plant converts sunlight directly into electricity with photovoltaic panels. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 41.8°N — which shapes how much energy it can produce and how its output varies through the year.

14.0°Cannual mean temp
1,894heating degree-days (base 18°C)
444cooling degree-days (base 18°C)
307 melevation

Monthly mean temperature

J: 6 °CJF: 7 °CFM: 9 °CMA: 12 °CAM: 16 °CMJ: 20 °CJJ: 23 °CJA: 24 °CAS: 20 °CSO: 15 °CON: 10 °CND: 7 °CD24 °C

Heating degree-days here run 23% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 41/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

In colder climates, uninsulated hot equipment (boilers, turbines, valves, steam lines) loses proportionally more heat to ambient air — exactly the loss Inzonex modular insulation is designed to cut.

Solar PV loses ~0.35%/°C above 25°C cell temperature — roughly 0.0% at warm-season highs here (estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

How it compares & nearby plants

The #23 largest solar power plant of 223 in Italy by capacity.

Italy has 223 solar power plants in this dataset, together about 1,953 MW of capacity.

Nearby power plants

Location

Coordinates 41.758, 13.013 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Built from open public data; no personal information. Operate this site? Request a correction or removal.