Home / Hong Kong / CKI Lamma power station

CKI Lamma power station

Gas power plant in Hong Kong, Hong Kong. Approximate location 22.2188909, 114.1082183.

GasHong KongHong KongCCGT · HRSGMitsubishi Heavy Industries: M701F

CKI Lamma power station is a 3,260 MW gas power station in Hong Kong, Hong Kong. It is operated by Hong Kong Electric Co Ltd [100%]. Based on its capacity (estimated), it can supply roughly 3.7 million homes (estimated). It ranks #3 of 4 Hong Kong power plants by installed capacity. Commissioned in 1991, it is around 35 years old — long-established.

3,260Legacy source-record capacity
4HRSG unit(s)
3,671,691homes powered (est.)
1991commissioned (~35 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_ckilamma_hongko.

Data status

Known data

FacilityCKI Lamma power station GEM-GOGPT
CountryHong Kong · Hong Kong GEM-GOGPT
Coordinates22.2188909, 114.1082183 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity3,260 MW GEM-GOGPT source record; scope not independently normalised
OwnerHong Kong Electric Co Ltd [100%] GEM-GOGPT
Commissioned1991 GEM-GOGPT
TechnologyCCGT · Mitsubishi Heavy Industries: M701F · HRSG GEM-GOGPT

Calculated from dataset

CO₂ emissions5,140,368 t CO₂/yr calculated
Capacity rank in country#3 of 4 calculated
Fuel-specific rank in country#2 of 2 calculated
Homes-powered equivalent3,671,691 calculated
Climate22.2°C · HDD 198 derived from coordinates
Environmental severityC5 · 54/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 1,995 MW for CKI Lamma power station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Capacity claim grade: B_SCOPE_PARENT_COMPLEX - recommended action: build_parent_complex_model - confidence: not_comparable_without_scope. This follows a claim-based data model: value + scope + source + confidence, rather than silently overwriting records.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: GEM-GOGPT source-record capacity (not GEM location-aggregated); fuel: GEM-GOGPT source-record fuel

In context: how this plant compares

Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG); Mitsubishi Heavy Industries: M701F. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Hong Kong

Black Point power station: 3,800 MW4kBlack Poin…CKI Lamma power station: 3,260 MW3kCKI Lamma …

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Hong Kong Electric Co Ltd [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical (dry winter) climate (Köppen Cwa) — Northern Hemisphere, latitude 22.2°N — which shapes how much energy it can produce and how its output varies through the year.

22.2°Cannual mean temp
198heating degree-days (base 18°C)
1,732cooling degree-days (base 18°C)
124 melevation

Monthly mean temperature

J: 15 °CJF: 15 °CFM: 18 °CMA: 22 °CAM: 25 °CMJ: 27 °CJJ: 28 °CJA: 28 °CAS: 27 °CSO: 24 °CON: 20 °CND: 17 °CD28 °C

Heating degree-days here run 92% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 16/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~5% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
54/100environmental-severity index
12.6°Cseasonal temperature swing
15 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest gas power plant of 2 in Hong Kong by capacity.

Hong Kong has 2 gas power plants in this dataset, together about 7,060 MW of capacity.

Nearby power plants

Location

Coordinates 22.2188909, 114.1082183 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is CKI Lamma power station?

CKI Lamma power station is a 3,260 MW source-record gas power plant in Hong Kong, Hong Kong, commissioned in 1991.

How many homes can CKI Lamma power station power?

Its output is enough to supply roughly 3,671,691 homes (estimated).

Who operates CKI Lamma power station?

CKI Lamma power station is operated by Hong Kong Electric Co Ltd [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.