Home / Europe / Spain / CAS TRESORER TG3 CC2

CAS TRESORER TG3 CC2

Gas power plant in Balearic Islands, Spain. Approximate location 39.5672, 2.6895.

GasBalearic IslandsSpainCCGT · HRSGCO₂ measured

CAS TRESORER TG3 CC2 is a 460 MW gas power station in Balearic Islands, Spain. It is operated by ENDESA GENERACION S.A.. Based on its capacity (estimated), it can supply roughly 518k homes (estimated). It ranks #64 of 899 Spain power plants by installed capacity. Commissioned in 2009, it is around 17 years old — relatively modern. Its annual emissions of 794,743 t CO₂/yr (EU ETS verified (EUTL 2023)) are equivalent to about 185k cars driven for a year. In context, gas supplies about 21.6% of Spain's electricity; the national grid averages 154 gCO₂/kWh (74.6% low-carbon) (2025).

460Source-backed capacity
2HRSG unit(s)
518,091homes powered (est.)
794,743t CO₂ / yr (EU ETS verified (EUTL 2023))
2009commissioned (~17 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1006309.

Data status

Known data

FacilityCAS TRESORER TG3 CC2 WRI
CountrySpain · Balearic Islands WRI
Coordinates39.5672, 2.6895 WRI
FuelGas WRI
MW installed capacity460 MW WRI source record; scope not independently normalised
OwnerENDESA GENERACION S.A. WRI
Commissioned2009 WRI
TechnologyCCGT · HRSG WRI
CO₂ emissions794,743 t CO₂/yr measured · EU ETS verified (EUTL 2023)

Calculated from dataset

Capacity rank in country#64 of 899 calculated
Fuel-specific rank in country#29 of 95 calculated
Capacity vs country/fuel peers8.52× · 54 MW median · 95 peers calculated
Homes-powered equivalent518,091 calculated
Climate16.3°C · HDD 1,197 derived from coordinates
Environmental severityC4 · 40/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000401420); fuel: WRI source-record fuel

In context: how this plant compares

At 460 MW, CAS TRESORER TG3 CC2 is well above the median gas plant in Spain (54 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

794,743 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

185kpassenger cars driven for a year
104khomes' yearly energy use
13 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per EU ETS verified (EUTL 2023) (measured for US EPA/EU ETS, modelled for Climate TRACE).

Capacity vs largest gas plants in Spain

BESOS GRUPO 5: 1,671 MW2kBESOS GRU…ARCOS DE LA FRONTERA GRUPO 1: 1,585 MW2kARCOS DE L…CARTAGENA GRUPO 1: 1,249 MW1kCARTAGENA …Cartagena (Escombreras) power station: 1,249 MW1kCartagena …CCC SAGUNTO GRUPO 2: 1,232 MW1kCCC SAGUNT…ESCOMBRERAS GRUPO 1: 1,199 MW1kESCOMBRERA…El Fangal power station: 1,199 MW1kEl Fangal …PALOS DE LA FRONTERA GRUPO 1: 1,167 MW1kPALOS DE L…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by ENDESA GENERACION S.A.. All plants by this company →

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a hot-summer Mediterranean climate (Köppen Csa) — Northern Hemisphere, latitude 39.6°N — which shapes how much energy it can produce and how its output varies through the year.

16.3°Cannual mean temp
1,197heating degree-days (base 18°C)
595cooling degree-days (base 18°C)
94 melevation

Monthly mean temperature

J: 10 °CJF: 10 °CFM: 11 °CMA: 13 °CAM: 17 °CMJ: 21 °CJJ: 24 °CJA: 25 °CAS: 22 °CSO: 18 °CON: 14 °CND: 11 °CD25 °C

Heating degree-days here run 51% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 29/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~1% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with marine corrosion the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
40/100environmental-severity index
14.7°Cseasonal temperature swing
21 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #29 largest gas power plant of 95 in Spain by capacity.

Spain has 95 gas power plants in this dataset, together about 32,018 MW of capacity.

Nearby power plants

Location

Coordinates 39.5672, 2.6895 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is CAS TRESORER TG3 CC2?

CAS TRESORER TG3 CC2 is a 460 MW source-record gas power plant in Balearic Islands, Spain, commissioned in 2009.

How many homes can CAS TRESORER TG3 CC2 power?

Its output is enough to supply roughly 518,091 homes (estimated).

Who operates CAS TRESORER TG3 CC2?

CAS TRESORER TG3 CC2 is operated by ENDESA GENERACION S.A..

How much CO₂ does CAS TRESORER TG3 CC2 emit?

CAS TRESORER TG3 CC2 has measured emissions of about 794,743 tonnes of CO₂ per year (EU ETS verified (EUTL 2023)).

Built from open public data; no personal information. Operate this site? Request a correction or removal.