Home / Africa / Tunisia / Bouchemma 1

Bouchemma 1

Gas power plant in Qabis, Tunisia. Approximate location 33.9181, 10.0376.

GasQabisTunisiaOCGT

Bouchemma 1 is a 185 MW gas power station in Qabis, Tunisia. It is operated by Tunisian Company of Electricity and Gas [100%]. Based on its capacity (estimated), it can supply roughly 208k homes (estimated). It ranks #14 of 30 Tunisia power plants by installed capacity. Commissioned in 1977, it is around 49 years old — long-established. In context, gas supplies about 94.9% of Tunisia's electricity; the national grid averages 560 gCO₂/kWh (4.0% low-carbon) (2025).

185Source-backed capacity
208,362homes powered (est.)
1977commissioned (~49 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1023604.

Data status

Known data

FacilityBouchemma 1 WRI
CountryTunisia · Qabis WRI
Coordinates33.9181, 10.0376 WRI
FuelGas WRI
MW installed capacity185 MW WRI source record; scope not independently normalised
OwnerTunisian Company of Electricity and Gas [100%] WRI
Commissioned1977 WRI
TechnologyOCGT WRI

Calculated from dataset

CO₂ emissions291,708 t CO₂/yr calculated
Capacity rank in country#14 of 30 calculated
Fuel-specific rank in country#14 of 22 calculated
Capacity vs country/fuel peers0.52× · 357 MW median · 22 peers calculated
Homes-powered equivalent208,362 calculated
Climate20.0°C · HDD 582 derived from coordinates
Environmental severityC5 · 58/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000406167); fuel: WRI source-record fuel

In context: how this plant compares

At 185 MW, Bouchemma 1 is below the median gas plant in Tunisia (357 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Tunisia

Rades A1: 700 MW700Rades A1Mornaguia power station: 624 MW624Mornaguia …Bir Mcherga 1: 496 MW496Bir Mcherg…IPP Rades 2: 470 MW470IPP Rades 2Skhira 1 power station: 450 MW450Skhira 1 p…Skhira 2 power station: 450 MW450Skhira 2 p…Sousse C: 424 MW424Sousse CSousse D: 424 MW424Sousse D

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Tunisian Company of Electricity and Gas [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a hot desert climate (Köppen BWh) — Northern Hemisphere, latitude 33.9°N — which shapes how much energy it can produce and how its output varies through the year.

20.0°Cannual mean temp
582heating degree-days (base 18°C)
1,339cooling degree-days (base 18°C)
29 melevation

Monthly mean temperature

J: 12 °CJF: 13 °CFM: 15 °CMA: 18 °CAM: 22 °CMJ: 25 °CJJ: 28 °CJA: 29 °CAS: 26 °CSO: 22 °CON: 17 °CND: 13 °CD29 °C

Heating degree-days here run 76% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 22/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~4% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
58/100environmental-severity index
16.6°Cseasonal temperature swing
41 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #14 largest gas power plant of 22 in Tunisia by capacity.

Tunisia has 22 gas power plants in this dataset, together about 6,360 MW of capacity.

Nearby power plants

Location

Coordinates 33.9181, 10.0376 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Bouchemma 1?

Bouchemma 1 is a 185 MW source-record gas power plant in Qabis, Tunisia, commissioned in 1977.

How many homes can Bouchemma 1 power?

Its output is enough to supply roughly 208,362 homes (estimated).

Who operates Bouchemma 1?

Bouchemma 1 is operated by Tunisian Company of Electricity and Gas [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.