Home / United States / Food & beverage plants / Tropicana Manufacturing Co Inc

Tropicana Manufacturing Co Inc — United States

Food & Beverage in United States. Approximate location 27.48702, -82.55117.

Food & BeverageUnited StatesCO₂ estimate (modelled)

Tropicana Manufacturing Co Inc is a food & beverage plant in United States. Its listed capacity is 1,864,960,106 USD. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously. By capacity it ranks #21 among 391 food & beverage plants in United States. It emits about 151,559 t CO₂e a year from Climate TRACE. That is 0.03% of the CO₂e from the 1,910 facilities in United States that have an emissions figure in IndustryAtlas.

151,559t CO₂e / yr (Climate TRACE)
#519CO₂ rank in United States

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38481758.

Data status

Known source data

FacilityTropicana Manufacturing Co Inc Climate TRACE
CountryUnited States Climate TRACE
Coordinates27.48702, -82.55117 Climate TRACE
Sector / subsectorfood-beverage-tobacco Climate TRACE
Reported capacity1,864,960,106 USD Climate TRACE
EPA parent companyTropicana Manufacturing Co, Inc US EPA GHGRP
EPA NAICS311421 US EPA GHGRP
TRI facility recordTROPICANA MANUFACTURING CO INC US EPA TRI
TRI parent companyTROPICANA PRODUCTS INC US EPA TRI
TRI NAICS311411 US EPA TRI
TRI reported chemicalsAmmonia, Nitrate compounds (water dissociable; reportable only when in aqueous solution), Nitric acid, Peracetic acid US EPA TRI
TRI on-site releases36,413 lb/yr US EPA TRI
Modelled CO₂e151,559 t/yr Climate TRACE
Measured CO₂ cross-check125,623 t/yr measured cross-check · GHGRP 2023

Calculated from the dataset

United States rank#519 of 1910 · top 27.2% calculated
Global food-beverage-tobacco rank#63 of 560 · top 11.2% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

At 1,864,960,106 USD, Tropicana Manufacturing Co Inc is well above the median food & beverage plant in United States (452,469,926 USD). Subsector: food-beverage-tobacco. As food & beverage plant, it requires high process heat (typically 80–200°C) for its core industrial operations, supplied by boilers, furnaces or direct combustion. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 151,559 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

2.8kmillion cubic feet of natural gas burned
32khomes' electricity use for a year
152kacres of US forest absorbing CO₂ for a year

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost and Scope 1 emissions

At its reported 152k t CO₂e/yr (Scope 1), Tropicana Manufacturing Co Inc carries no domestic carbon price, and its products are not CBAM-covered goods, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €11.4M/yr.

Measured CO₂: 126k t/yr — verified GHGRP (reporting year 2023) (17% below the modelled estimate). Modelled estimate 152k t/yr (Climate TRACE), high-confidence match, cross-checked via the measured-vs-modelled dataset (n=711).

152k t CO₂e / yrScope 1 emissions
€11.4M/yrindicative carbon value (not a CBAM liability)

Carbon price: EU CBAM €75/t · EU ETS €85/t, September 10, 2026, refreshed live via Carbon Hub. CO₂: measured (GHGRP RY2023), cross-checked vs Climate TRACE. Indicative carbon value, not the cash bill — free allocation applies; not compliance advice.

Parent company

Tropicana Manufacturing Co, Inc US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

Tropicana Manufacturing Co Inc sits in a humid subtropical climate zone (Köppen Cfa), at 27.5°N in the northern hemisphere.

~18°Ctypical annual mean
~27°Ctypical warm-season
Humid subtropical: hot summers and mild winters

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
48/100environmental-severity index
11.7°Cseasonal temperature swing
32 kmdistance to coast
Very highCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1273 W/m² to ambient — roughly 0.98× the loss at a 20 °C reference. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 27.48702, -82.55117. View on OpenStreetMap.

Frequently asked questions

What type of facility is Tropicana Manufacturing Co Inc?

Tropicana Manufacturing Co Inc is a food & beverage plant in United States. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously.

How much CO₂ does Tropicana Manufacturing Co Inc emit?

The page uses about 151,559 t CO₂e/year from the open dataset It ranks #519 among facilities in United States by estimated CO₂.

Where is Tropicana Manufacturing Co Inc located?

Tropicana Manufacturing Co Inc is in United States at approximately 27.48702, -82.55117.

Built from open public data; no personal information. Operate this site? Request a correction or removal.