Home / United States / Lime plants / Western Sugar Cooperative Lovell

Western Sugar Cooperative Lovell

Lime Plant in United States. Approximate location 44.83787, -108.40429.

Lime PlantUnited StatesCO₂ not individually reported

Western Sugar Cooperative Lovell is a lime plant in United States. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture. No facility-measured CO₂ figure is available in the open dataset used here.

CO₂ not individually reported — Climate TRACE covers this sector only in aggregate

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38468955.

Data status

Known source data

FacilityWestern Sugar Cooperative Lovell Climate TRACE
CountryUnited States Climate TRACE
Coordinates44.83787, -108.40429 Climate TRACE
Sector / subsectorlime Climate TRACE
EPA parent companyTHE WESTERN SUGAR COOPERATIVE US EPA GHGRP
EPA NAICS311313 US EPA GHGRP
TRI facility recordWESTERN SUGAR COOPERATIVE LOVELL FACTORY US EPA TRI
TRI parent companyWESTERN SUGAR COOPERATIVE US EPA TRI
TRI NAICS311313 US EPA TRI
TRI reported chemicalsAmmonia US EPA TRI
TRI on-site releases40,636 lb/yr US EPA TRI

Calculated from the dataset

Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: lime. As lime plant, it requires high process heat (typically 600–900°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

Carbon & decarbonization context

No facility-measured CO₂ is published for Western Sugar Cooperative Lovell; Climate TRACE provides only a lime plant sector-level estimate, so a precise per-site figure, ranking or carbon cost would be misleading and is not shown. The decarbonization lever is the same regardless: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂, with payback up to 2 years. No domestic carbon price — but cement, steel, aluminium, fertilizer and hydrogen exported to the EU face CBAM at €75/t (rising to 100% by 2034).

CO₂: Climate TRACE sector-level estimate (not facility-measured). Estimate the saving for this site →

Parent company

The Western Sugar Cooperative US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

Western Sugar Cooperative Lovell sits in a cold desert climate zone (Köppen BWk), at 44.8°N in the northern hemisphere.

~11°Ctypical annual mean
~26°Ctypical warm-season
Cold desert: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
38/100environmental-severity index
27.8°Cseasonal temperature swing
1110 kmdistance to coast
LowCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1432 W/m² to ambient — roughly 1.10× the loss at a 20 °C reference; removable insulation recovers about 1360 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 44.83787, -108.40429. View on OpenStreetMap.

Heat loss & insulation profile

For a lime plant, the main modular-insulation targets are kiln, preheater, hot-gas ducting, valves & dampers. Typical hot-surface ranges used for screening: 200–900 °C.

calcination-heavy like cement; fuel side only.

Indicative recoverable energy

A first-pass insulation screen suggests about 6,500 MWh/year of recoverable heat-loss reduction and about 2,200 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

United States: funding & obligation

Funding. Investment tax credit up to 30% of qualified investment incl. industrial decarbonization; open to small/medium/large manufacturers. official source · verified 2026
Status: ~$6B of $10B allocated Jan-2025; remaining capacity + IRA status under political review — verify before 'apply now'.

Obligation. None at federal level (voluntary). Some states have their own programs. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Western Sugar Cooperative Lovell?

Western Sugar Cooperative Lovell is a lime plant in United States. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

How much CO₂ does Western Sugar Cooperative Lovell emit?

The open dataset used here does not include a facility-level CO₂ value for Western Sugar Cooperative Lovell.

Where is Western Sugar Cooperative Lovell located?

Western Sugar Cooperative Lovell is in United States at approximately 44.83787, -108.40429.

Built from open public data; no personal information. Operate this site? Request a correction or removal.