US ARMY RADFORD ARMY AMMUNITION PLANT is an other manufacturing in United States. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control. It emits about 151,121 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 35k passenger cars.

151,121t CO₂e / yr (Climate TRACE)
#521CO₂ rank in United States

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-3194347.

Data status

Known source data

FacilityUS ARMY RADFORD ARMY AMMUNITION PLANT Climate TRACE
CountryUnited States Climate TRACE
Coordinates37.18056, -80.54111 Climate TRACE
Sector / subsectorother-manufacturing Climate TRACE
EPA parent companyUS GOVERNMENT US EPA GHGRP
EPA NAICS325920 US EPA GHGRP
Modelled CO₂e151,121 t/yr Climate TRACE
Measured CO₂ cross-check157,526 t/yr measured cross-check · GHGRP 2023

Calculated from the dataset

United States rank#521 of 1910 · top 27.3% calculated
Global other-manufacturing rank#14 of 398 · top 3.5% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: other-manufacturing. As other manufacturing, it requires high process heat (typically 100–600°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 151,121 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

35kcars driven for a year
20khomes' annual energy use
2.5 milliontree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 151k t CO₂e/yr (Scope 1), US ARMY RADFORD ARMY AMMUNITION PLANT carries no domestic carbon price; other manufacturings are not a CBAM-covered good, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €11.4M/yr. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈3k t–8k t/yr, worth €228k€569k, with payback up to 2 years. No domestic carbon price — but cement, steel, aluminium, fertilizer and hydrogen exported to the EU face CBAM at €75/t (rising to 100% by 2034).

Measured CO₂: 158k t/yr — verified GHGRP (reporting year 2023) (4% above the modelled estimate). Modelled estimate 151k t/yr (Climate TRACE), high-confidence match, cross-checked via the measured-vs-modelled dataset (n=711).

151k t CO₂e / yrScope 1 emissions
€11.4M/yrindicative carbon value (not a CBAM liability)
3k t–8k t/yr ≈ €228k€569kDecarbonization potential

Carbon price: EU CBAM €75/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: measured (GHGRP RY2023), cross-checked vs Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Parent company

Us Government US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

US ARMY RADFORD ARMY AMMUNITION PLANT sits in a temperate oceanic climate zone (Köppen Cfb), at 37.2°N in the northern hemisphere.

~11°Ctypical annual mean
~18°Ctypical warm-season
Temperate oceanic: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
31/100environmental-severity index
22.0°Cseasonal temperature swing
440 kmdistance to coast
LowCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1386 W/m² to ambient — roughly 1.07× the loss at a 20 °C reference; removable insulation recovers about 1317 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 37.18056, -80.54111. View on OpenStreetMap.

Heat loss & insulation profile

For a other manufacturing, the main modular-insulation targets are process heaters, ovens, steam lines, hot-water systems, valves & flanges. Typical hot-surface ranges used for screening: 80–300 °C.

Indicative recoverable energy

A first-pass insulation screen suggests about 2,000 MWh/year of recoverable heat-loss reduction and about 400 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

United States: funding & obligation

Funding. Investment tax credit up to 30% of qualified investment incl. industrial decarbonization; open to small/medium/large manufacturers. official source · verified 2026
Status: ~$6B of $10B allocated Jan-2025; remaining capacity + IRA status under political review — verify before 'apply now'.

Obligation. None at federal level (voluntary). Some states have their own programs. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is US ARMY RADFORD ARMY AMMUNITION PLANT?

US ARMY RADFORD ARMY AMMUNITION PLANT is a other manufacturing in United States. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control.

How much CO₂ does US ARMY RADFORD ARMY AMMUNITION PLANT emit?

The page uses about 151,121 t CO₂e/year from the open dataset It ranks #521 among facilities in United States by estimated CO₂.

Where is US ARMY RADFORD ARMY AMMUNITION PLANT located?

US ARMY RADFORD ARMY AMMUNITION PLANT is in United States at approximately 37.18056, -80.54111.

Built from open public data; no personal information. Operate this site? Request a correction or removal.