Home / Europe / Italy / Lime plants / Lime & Cork

Lime & Cork

Lime Plant in Italy. Approximate location 43.69656, 12.86541.

Lime PlantItalyCO₂ not individually reported

Lime & Cork is a lime plant in Italy. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture. No facility-measured CO₂ figure is available in the open dataset used here.

CO₂ not individually reported — Climate TRACE covers this sector only in aggregate

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-31715540.

Data status

Known source data

FacilityLime & Cork Climate TRACE
CountryItaly Climate TRACE
Coordinates43.69656, 12.86541 Climate TRACE
Sector / subsectorlime Climate TRACE

Calculated from the dataset

Climate contextderived from coordinates calculated

Not available

Owner / operatorNot available not in dataset
Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: lime. As lime plant, it requires high process heat (typically 600–900°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

Carbon & decarbonization context

No facility-measured CO₂ is published for Lime & Cork; Climate TRACE provides only a lime plant sector-level estimate, so a precise per-site figure, ranking or carbon cost would be misleading and is not shown. The decarbonization lever is the same regardless: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂, with payback up to 2 years.

CO₂: Climate TRACE sector-level estimate (not facility-measured). Estimate the saving for this site →

Local climate

Lime & Cork sits in a temperate oceanic climate zone (Köppen Cfb), at 43.7°N in the northern hemisphere.

~11°Ctypical annual mean
~18°Ctypical warm-season
Temperate oceanic: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
40/100environmental-severity index
18.5°Cseasonal temperature swing
31 kmdistance to coast
HighCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1364 W/m² to ambient — roughly 1.05× the loss at a 20 °C reference; removable insulation recovers about 1296 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 43.69656, 12.86541. View on OpenStreetMap.

Heat loss & insulation profile

For a lime plant, the main modular-insulation targets are kiln, preheater, hot-gas ducting, valves & dampers. Typical hot-surface ranges used for screening: 200–900 °C.

calcination-heavy like cement; fuel side only.

Indicative recoverable energy

A first-pass insulation screen suggests about 6,500 MWh/year of recoverable heat-loss reduction and about 2,200 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

Italy: funding & obligation

Funding. MIMIT plan (~EUR 12.7B): tax credits for efficiency/decarbonization investments (requires a certified energy diagnosis to access). official source · verified 2026
Status: Plan window/budget evolving — confirm current terms.

Obligation. Mandatory energy diagnosis every 4 yrs for large enterprises (>250 staff or >EUR 50M) and energy-intensive companies (>10 TJ/yr from 2026); ENEA penalties up to EUR 40,000. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). official source · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Lime & Cork?

Lime & Cork is a lime plant in Italy. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

How much CO₂ does Lime & Cork emit?

The open dataset used here does not include a facility-level CO₂ value for Lime & Cork.

Where is Lime & Cork located?

Lime & Cork is in Italy at approximately 43.69656, 12.86541.

Built from open public data; no personal information. Operate this site? Request a correction or removal.