Home / Europe / Italy / Chemical plants / Ferrara Fertilizers facility

Ferrara Fertilizers facility

Chemical Plant in Italy. Approximate location 44.85813, 11.59357.

Chemical PlantItalyCO₂ estimate (modelled)

Ferrara Fertilizers facility is a chemical plant in Italy. Its listed capacity is 544,310 t of chemical. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations. It is operated by Yara International ASA. By capacity it ranks #2 among 2 chemical plants in Italy. It emits about 514,800 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 120k passenger cars. Its CO₂ per unit of capacity is 34% below the national median for this sector.

544,310t of chemical
514,800t CO₂e / yr (Climate TRACE)
#19CO₂ rank in Italy
0.95t CO₂ per capacity unit

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-45257079.

Data status

Known source data

FacilityFerrara Fertilizers facility Climate TRACE
CountryItaly Climate TRACE
Coordinates44.85813, 11.59357 Climate TRACE
Sector / subsectorchemicals Climate TRACE
Reported capacity544,310 t of chemical Climate TRACE
Owner / operatorYara International ASA Climate TRACE
Modelled CO₂e514,800 t/yr Climate TRACE

Calculated from the dataset

Italy rank#19 of 70 · top 27.1% calculated
Global chemicals rank#206 of 393 · top 52.4% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

At 544,310 t of chemical, Ferrara Fertilizers facility is around the median chemical plant in Italy (633,960 t of chemical). Subsector: chemicals. As chemical plant, it requires high process heat (typically 100–500°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 514,800 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

120kcars driven for a year
67khomes' annual energy use
8.6 milliontree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 515k t CO₂e/yr (Scope 1), Ferrara Fertilizers facility carries €40.9M/yr of carbon at the full EU ETS price (€79/t CO₂). Free allocation phases out to 2034 (Reg. (EU) 2023/956), so today's bill is lower and rising toward this full-price figure. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈10k t–26k t/yr, worth €818k€2.0M, with payback up to 2 years.

515k t CO₂e / yrScope 1 emissions
€40.9M/yrcarbon value · full EU ETS price
10k t–26k t/yr ≈ €818k€2.0MDecarbonization potential

Carbon price: EU ETS €79/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Capacity vs largest chemical plants in Italy

Italy: 633,960 t of chemical634kItalyFerrara Fertilizers facility: 544,310 t of chemical544kFerrara Fe…

Listed capacity (t of chemical), Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0).

Operator

Operated by Yara International ASA. All facilities by this operator →

Local climate

Ferrara Fertilizers facility sits in a humid subtropical climate zone (Köppen Cfa), at 44.9°N in the northern hemisphere.

~18°Ctypical annual mean
~27°Ctypical warm-season
Humid subtropical: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
37/100environmental-severity index
21.6°Cseasonal temperature swing
92 kmdistance to coast
ModerateCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1363 W/m² to ambient — roughly 1.05× the loss at a 20 °C reference; removable insulation recovers about 1295 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

The #2 largest of 2 chemical plants in Italy by listed capacity (Climate TRACE).

Nearby industrial sites

Location

Coordinates 44.85813, 11.59357. View on OpenStreetMap.

Heat loss & insulation profile

For a chemical plant, the main modular-insulation targets are reactors, crackers, distillation columns, heat exchangers, steam lines, valves & flanges. Typical hot-surface ranges used for screening: 150–500 °C.

Indicative recoverable energy

A first-pass insulation screen suggests about 15,000 MWh/year of recoverable heat-loss reduction and about 3,000 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

Italy: funding & obligation

Funding. MIMIT plan (~EUR 12.7B): tax credits for efficiency/decarbonization investments (requires a certified energy diagnosis to access). official source · verified 2026
Status: Plan window/budget evolving — confirm current terms.

Obligation. Mandatory energy diagnosis every 4 yrs for large enterprises (>250 staff or >EUR 50M) and energy-intensive companies (>10 TJ/yr from 2026); ENEA penalties up to EUR 40,000. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). official source · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Ferrara Fertilizers facility?

Ferrara Fertilizers facility is a chemical plant in Italy. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

What capacity is listed for Ferrara Fertilizers facility?

The open dataset lists 544,310 t of chemical of capacity for Ferrara Fertilizers facility.

How much CO₂ does Ferrara Fertilizers facility emit?

The page uses about 514,800 t CO₂e/year from the open dataset It ranks #19 among facilities in Italy by estimated CO₂.

Where is Ferrara Fertilizers facility located?

Ferrara Fertilizers facility is in Italy at approximately 44.85813, 11.59357.

Who operates Ferrara Fertilizers facility?

The operator recorded in the open dataset is Yara International ASA.