DARTCO OF TEXAS WAXAHACHIE SITE — United States
Other Manufacturing in United States. Approximate location 32.42694, -96.85.
Other ManufacturingUnited StatesCO₂ estimate (modelled)
DARTCO OF TEXAS WAXAHACHIE SITE is a manufacturing plant in United States. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control. It emits about 31,666 t CO₂e a year from Climate TRACE.
Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-3192967.
Data status
Known source data
Calculated from the dataset
Not available
Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.
Similar facilities by modelled emissions
- Wyman-Gordon Company · 31,513 t CO₂e/yr · United States
- NISSAN NORTH AMERICA INC, CANTON MANUFACTURING FACILITY · 31,842 t CO₂e/yr · United States
- SI GROUP INC /ROTT JCT FAC · 31,998 t CO₂e/yr · United States
- SUMITOMO RUBBER USA, LLC · 31,252 t CO₂e/yr · United States
- SOUTHWIRE COMPANY · 32,125 t CO₂e/yr · United States
Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.
Operating power plants within 50 km
- Midlothian Energy Facility · Gas · 1,734 MW · 19 km
- Ennis Power Company LLC · Gas · 418 MW · 20 km
- Skyline Gas Recovery · Waste · 6 MW · 21 km
- Ameresco Dallas LLC · Waste · 4 MW · 31 km
- Mountain Creek · Gas · 853 MW · 34 km
PowerAtlas operating assets, ordered by great-circle distance from published coordinates.
In context: how this facility compares
Subsector: other-manufacturing. As manufacturing plant, it requires high process heat (typically 100–600°C) for its core industrial operations, supplied by boilers, furnaces or direct combustion. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control.
Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.
What 31,666 t CO₂e a year looks like
This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:
Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.
Carbon cost and Scope 1 emissions
At its reported 32k t CO₂e/yr (Scope 1), DARTCO OF TEXAS WAXAHACHIE SITE carries no domestic carbon price, and its products are not CBAM-covered goods, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €2.4M/yr.
Carbon price: EU CBAM €75/t · EU ETS €85/t, September 10, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Indicative carbon value, not the cash bill — free allocation applies; not compliance advice.
Parent company
Dart Container Corp US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.
Local climate
DARTCO OF TEXAS WAXAHACHIE SITE sits in a humid subtropical climate zone (Köppen Cfa), at 32.4°N in the northern hemisphere.
Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).
Site climate & environmental severity
This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.
In this site’s local climate, a bare 150 °C surface sheds about 1314 W/m² to ambient — roughly 1.01× the loss at a 20 °C reference. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).
Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.
How it compares & nearby sites
Nearby industrial sites
- Fran'S Fryers, Inc. · Food & Beverage
- Midlothian Cement Plant · Cement Plant · 610,295 t CO₂
- Midlothian Cement Plant · Cement Plant · 550,689 t CO₂
- Gerdau Midlothian Steel Mill · Steel Plant · 83,254 t CO₂
- Midlothian Cement Plant · Cement Plant · 173,240 t CO₂
- Dallas Overhaul Center · Other Manufacturing · 28,482 t CO₂
Location
Coordinates 32.42694, -96.85. View on OpenStreetMap. Location shown at industrial-zone / municipality precision (shared source geocode).
Frequently asked questions
What type of facility is DARTCO OF TEXAS WAXAHACHIE SITE?
DARTCO OF TEXAS WAXAHACHIE SITE is a manufacturing plant in United States. Heavy manufacturing facilities run a range of heat-intensive processes (rubber, plastics, pressure vessels); maintaining process heat efficiently is critical to cost control.
How much CO₂ does DARTCO OF TEXAS WAXAHACHIE SITE emit?
The page uses about 31,666 t CO₂e/year from the open dataset It ranks #1340 among facilities in United States by estimated CO₂.
Where is DARTCO OF TEXAS WAXAHACHIE SITE located?
DARTCO OF TEXAS WAXAHACHIE SITE is in United States at approximately 32.42694, -96.85.