Home / United States / Non-ferrous metals plants / DALTON CORP WARSAW MFG FACILITY

DALTON CORP WARSAW MFG FACILITY — United States

Metals Plant in United States. Approximate location 41.23575, -85.83253.

Metals PlantUnited StatesCO₂ estimate (modelled)

DALTON CORP WARSAW MFG FACILITY is a non-ferrous metals plant in United States. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points. It emits about 19,837 t CO₂e a year from Climate TRACE.

19,837t CO₂e / yr (Climate TRACE)
#1633CO₂ rank in United States

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-3673261.

Data status

Known source data

FacilityDALTON CORP WARSAW MFG FACILITY Climate TRACE
CountryUnited States Climate TRACE
Coordinates41.23575, -85.83253 Climate TRACE
Sector / subsectorother-metals Climate TRACE
EPA parent companyNEW DALTON HOLDINGS CORP US EPA GHGRP
EPA NAICS331511 US EPA GHGRP
TRI facility recordDALTON CORP WARSAW MANUFACTURING FACILITY US EPA TRI
TRI parent companyDALTON CORP US EPA TRI
TRI NAICS331511 US EPA TRI
TRI reported chemicalsChromium, Copper, Diisocyanates, Lead, Manganese And Manganese Compounds, Mercury… US EPA TRI
TRI on-site releases7,389 lb/yr US EPA TRI
Modelled CO₂e19,837 t/yr Climate TRACE

Calculated from the dataset

United States rank#1633 of 1910 · top 85.5% calculated
Global other-metals rank#338 of 416 · top 81.2% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: other-metals. As non-ferrous metals plant, it requires high process heat (typically 400–1200°C) for its core industrial operations, supplied by boilers, furnaces or direct combustion. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 19,837 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

263tanker trucks of gasoline burned
4.6kgasoline cars driven for a year
331ktree seedlings grown for 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost and Scope 1 emissions

At its reported 20k t CO₂e/yr (Scope 1), DALTON CORP WARSAW MFG FACILITY carries no domestic carbon price, and its products are not CBAM-covered goods, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €1.5M/yr.

20k t CO₂e / yrScope 1 emissions
€1.5M/yrindicative carbon value (not a CBAM liability)

Carbon price: EU CBAM €75/t · EU ETS €85/t, September 10, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Indicative carbon value, not the cash bill — free allocation applies; not compliance advice.

Parent company

New Dalton Holdings Corp US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

DALTON CORP WARSAW MFG FACILITY sits in a hot-summer humid continental climate zone (Köppen Dfa), at 41.2°N in the northern hemisphere.

~9°Ctypical annual mean
~23°Ctypical warm-season
Hot-summer humid continental: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with thermal cycling the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
35/100environmental-severity index
27.5°Cseasonal temperature swing
143 kmdistance to coast
ModerateCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1405 W/m² to ambient — roughly 1.08× the loss at a 20 °C reference. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 41.23575, -85.83253. View on OpenStreetMap.

Frequently asked questions

What type of facility is DALTON CORP WARSAW MFG FACILITY?

DALTON CORP WARSAW MFG FACILITY is a non-ferrous metals plant in United States. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points.

How much CO₂ does DALTON CORP WARSAW MFG FACILITY emit?

The page uses about 19,837 t CO₂e/year from the open dataset It ranks #1633 among facilities in United States by estimated CO₂.

Where is DALTON CORP WARSAW MFG FACILITY located?

DALTON CORP WARSAW MFG FACILITY is in United States at approximately 41.23575, -85.83253.

Built from open public data; no personal information. Operate this site? Request a correction or removal.