Home / Europe / Netherlands / Chemical plants / Chemelot-Geleen Fertilizers facility

Chemelot-Geleen Fertilizers facility

Chemical Plant in Netherlands. Approximate location 50.97546, 5.80232.

Chemical PlantNetherlandsCO₂ estimate (modelled)

Chemelot-Geleen Fertilizers facility is a chemical plant in Netherlands. Its listed capacity is 965,000 t of chemical. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations. It is operated by OCI Nitrogen BV. By capacity it ranks #2 among 3 chemical plants in Netherlands. It emits about 1,333,822 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 311k passenger cars.

965,000t of chemical
1,333,822t CO₂e / yr (Climate TRACE)
#10CO₂ rank in Netherlands
1.38t CO₂ per capacity unit

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-45257055.

Data status

Known source data

FacilityChemelot-Geleen Fertilizers facility Climate TRACE
CountryNetherlands Climate TRACE
Coordinates50.97546, 5.80232 Climate TRACE
Sector / subsectorchemicals Climate TRACE
Reported capacity965,000 t of chemical Climate TRACE
Owner / operatorOCI Nitrogen BV Climate TRACE
Modelled CO₂e1,333,822 t/yr Climate TRACE

Calculated from the dataset

Netherlands rank#10 of 25 · top 40.0% calculated
Global chemicals rank#114 of 393 · top 29.0% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

At 965,000 t of chemical, Chemelot-Geleen Fertilizers facility is around the median chemical plant in Netherlands (965,000 t of chemical). Subsector: chemicals. As chemical plant, it requires high process heat (typically 100–500°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 1,333,822 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

311kcars driven for a year
174khomes' annual energy use
22 milliontree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 1.3M t CO₂e/yr (Scope 1), Chemelot-Geleen Fertilizers facility carries €106M/yr of carbon at the full EU ETS price (€79/t CO₂). Free allocation phases out to 2034 (Reg. (EU) 2023/956), so today's bill is lower and rising toward this full-price figure. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈27k t–67k t/yr, worth €2.1M€5.3M, with payback up to 2 years.

1.3M t CO₂e / yrScope 1 emissions
€106M/yrcarbon value · full EU ETS price
27k t–67k t/yr ≈ €2.1M€5.3MDecarbonization potential

Carbon price: EU ETS €79/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Capacity vs largest chemical plants in Netherlands

Yara Sluiskil: 1,900,000 t of chemical1.9MYara Sluis…Chemelot-Geleen Fertilizers facility: 965,000 t of chemical965kChemelot-G…Netherlands: 512,556 t of chemical513kNetherlands

Listed capacity (t of chemical), Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0).

Operator

Operated by OCI Nitrogen BV.

Local climate

Chemelot-Geleen Fertilizers facility sits in a temperate oceanic climate zone (Köppen Cfb), at 51.0°N in the northern hemisphere.

~11°Ctypical annual mean
~18°Ctypical warm-season
Temperate oceanic: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
28/100environmental-severity index
15.1°Cseasonal temperature swing
148 kmdistance to coast
ModerateCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1401 W/m² to ambient — roughly 1.08× the loss at a 20 °C reference; removable insulation recovers about 1331 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

The #2 largest of 3 chemical plants in Netherlands by listed capacity (Climate TRACE).

Nearby industrial sites

Location

Coordinates 50.97546, 5.80232. View on OpenStreetMap.

Heat loss & insulation profile

For a chemical plant, the main modular-insulation targets are reactors, crackers, distillation columns, heat exchangers, steam lines, valves & flanges. Typical hot-surface ranges used for screening: 150–500 °C.

Indicative recoverable energy

A first-pass insulation screen suggests about 25,000 MWh/year of recoverable heat-loss reduction and about 5,100 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

Netherlands: funding & obligation

Funding. Deduct 40% of qualifying Energy-List investment from taxable profit; 2026 budget EUR 460M; min EUR 2,500/asset. official source · verified 2026

Obligation. Large enterprises (>250 staff or >EUR 50M turnover / >EUR 43M balance) must audit every 4 yrs. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). official source · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Chemelot-Geleen Fertilizers facility?

Chemelot-Geleen Fertilizers facility is a chemical plant in Netherlands. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

What capacity is listed for Chemelot-Geleen Fertilizers facility?

The open dataset lists 965,000 t of chemical of capacity for Chemelot-Geleen Fertilizers facility.

How much CO₂ does Chemelot-Geleen Fertilizers facility emit?

The page uses about 1,333,822 t CO₂e/year from the open dataset It ranks #10 among facilities in Netherlands by estimated CO₂.

Where is Chemelot-Geleen Fertilizers facility located?

Chemelot-Geleen Fertilizers facility is in Netherlands at approximately 50.97546, 5.80232.

Who operates Chemelot-Geleen Fertilizers facility?

The operator recorded in the open dataset is OCI Nitrogen BV.

Built from open public data; no personal information. Operate this site? Request a correction or removal.