Home / United States / Lime plants / Carmeuse Lime & Stone Maysville Facility

Carmeuse Lime & Stone Maysville Facility

Lime Plant in United States. Approximate location 38.60778, -83.65134.

Lime PlantUnited States

Carmeuse Lime & Stone Maysville Facility is a lime plant in United States. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

0reported capacity — the source does not distinguish closed or idle; treat as historical/unverified

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38467361.

Data status

Known source data

FacilityCarmeuse Lime & Stone Maysville Facility Climate TRACE
CountryUnited States Climate TRACE
Coordinates38.60778, -83.65134 Climate TRACE
Sector / subsectorlime Climate TRACE
EPA parent companyCARMEUSE LIME INC US EPA GHGRP
EPA NAICS327410 US EPA GHGRP
TRI facility recordCARMEUSE LIME & STONE MAYSVILLE FACILITY US EPA TRI
TRI parent companyCARMEUSE NORTH AMERICA US EPA TRI
TRI NAICS327410 US EPA TRI
TRI reported chemicalsDioxin and dioxin-like compounds, Hydrochloric acid (acid aerosols including mists, vapors, gas, fog, and other airborne forms of any particle size), Lead compounds US EPA TRI
TRI on-site releases84,222 lb/yr US EPA TRI

Calculated from the dataset

Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: lime. As lime plant, it requires high process heat (typically 600–900°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

Parent company

Carmeuse Lime Inc US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

Carmeuse Lime & Stone Maysville Facility sits in a humid subtropical climate zone (Köppen Cfa), at 38.6°N in the northern hemisphere.

~18°Ctypical annual mean
~27°Ctypical warm-season
Humid subtropical: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
34/100environmental-severity index
25.0°Cseasonal temperature swing
317 kmdistance to coast
LowCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1381 W/m² to ambient — roughly 1.06× the loss at a 20 °C reference; removable insulation recovers about 1312 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 38.60778, -83.65134. View on OpenStreetMap.

Heat loss & insulation profile

For a lime plant, the main modular-insulation targets are kiln, preheater, hot-gas ducting, valves & dampers. Typical hot-surface ranges used for screening: 200–900 °C.

calcination-heavy like cement; fuel side only.

Indicative recoverable energy

A first-pass insulation screen suggests about 6,500 MWh/year of recoverable heat-loss reduction and about 2,200 t CO₂e/year of avoided emissions. Indicative range based on typical exposed hot equipment for this sector.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

United States: funding & obligation

Funding. Investment tax credit up to 30% of qualified investment incl. industrial decarbonization; open to small/medium/large manufacturers. official source · verified 2026
Status: ~$6B of $10B allocated Jan-2025; remaining capacity + IRA status under political review — verify before 'apply now'.

Obligation. None at federal level (voluntary). Some states have their own programs. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Carmeuse Lime & Stone Maysville Facility?

Carmeuse Lime & Stone Maysville Facility is a lime plant in United States. Lime plants calcine limestone in hot kilns at 800–900°C, and the hot quicklime must be handled in insulated vessels to prevent reaction with moisture.

Where is Carmeuse Lime & Stone Maysville Facility located?

Carmeuse Lime & Stone Maysville Facility is in United States at approximately 38.60778, -83.65134.

Built from open public data; no personal information. Operate this site? Request a correction or removal.