Argentina

Chemical Plant in Argentina. Approximate location -35.44682, -65.17536.

Chemical PlantArgentinaCO₂ estimate (modelled)

Argentina is a chemical plant in Argentina. Its listed capacity is 136,944 t of chemical. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations. By capacity it ranks #2 among 5 chemical plants in Argentina. It emits about 45,295 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 11k passenger cars. Its CO₂ per unit of capacity is 77% below the national median for this sector.

136,944t of chemical
45,295t CO₂e / yr (Climate TRACE)
#28CO₂ rank in Argentina
0.33t CO₂ per capacity unit

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-32267427.

Data status

Known source data

FacilityArgentina Climate TRACE
CountryArgentina Climate TRACE
Coordinates-35.44682, -65.17536 Climate TRACE
Sector / subsectorchemicals Climate TRACE
Reported capacity136,944 t of chemical Climate TRACE
Modelled CO₂e45,295 t/yr Climate TRACE

Calculated from the dataset

Argentina rank#28 of 33 · top 84.8% calculated
Global chemicals rank#364 of 393 · top 92.6% calculated
Climate contextderived from coordinates calculated

Not available

Owner / operatorNot available not in dataset
Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

In context: how this facility compares

At 136,944 t of chemical, Argentina is well above the median chemical plant in Argentina (6,396 t of chemical). Subsector: chemicals. As chemical plant, it requires high process heat (typically 100–500°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 45,295 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

11kcars driven for a year
5.9khomes' annual energy use
755ktree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 45k t CO₂e/yr (Scope 1), Argentina carries no domestic carbon price; chemical plants are not a CBAM-covered good, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €3.4M/yr. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈906 t–2k t/yr, worth €68k€171k, with payback up to 2 years. No domestic carbon price — but cement, steel, aluminium, fertilizer and hydrogen exported to the EU face CBAM at €75/t (rising to 100% by 2034).

45k t CO₂e / yrScope 1 emissions
€3.4M/yrindicative carbon value (not a CBAM liability)
906 t–2k t/yr ≈ €68k€171kDecarbonization potential

Carbon price: EU CBAM €75/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Capacity vs largest chemical plants in Argentina

ARG-Metán_ammonia: 790,380 t of chemical790kARG-Metán_…Argentina: 136,944 t of chemical137kArgentinaARG-Bahía Blanca_ammonia: 6,396 t of chemical6kARG-Bahía …ARG-Tercero Arriba_ammonia: 264 t of chemical264ARG-Tercer…ARG-San Lorenzo_methanol: 180 t of chemical180ARG-San Lo…

Listed capacity (t of chemical), Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0).

Local climate

Argentina sits in a humid subtropical climate zone (Köppen Cfa), at 35.4°S in the southern hemisphere.

~18°Ctypical annual mean
~27°Ctypical warm-season
Humid subtropical: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
33/100environmental-severity index
16.1°Cseasonal temperature swing
506 kmdistance to coast
ModerateCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1334 W/m² to ambient — roughly 1.03× the loss at a 20 °C reference; removable insulation recovers about 1267 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

The #2 largest of 5 chemical plants in Argentina by listed capacity (Climate TRACE).

Location

Coordinates -35.44682, -65.17536. View on OpenStreetMap.

Heat loss & insulation profile

For a chemical plant, the main modular-insulation targets are reactors, crackers, distillation columns, heat exchangers, steam lines, valves & flanges. Typical hot-surface ranges used for screening: 150–500 °C.

Indicative recoverable energy

A first-pass insulation screen suggests about 9,300 MWh/year of recoverable heat-loss reduction and about 1,900 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

External climate finance your country can access

For energy-efficiency projects around process heat, likely external funding channels include:

Sources: country climate-finance facilities and public development-bank programmes.

Frequently asked questions

What type of facility is Argentina?

Argentina is a chemical plant in Argentina. Chemical plants produce a wide range of industrial and specialty chemicals, many requiring precise temperature control and sustained heat input for reactions and separations.

What capacity is listed for Argentina?

The open dataset lists 136,944 t of chemical of capacity for Argentina.

How much CO₂ does Argentina emit?

The page uses about 45,295 t CO₂e/year from the open dataset It ranks #28 among facilities in Argentina by estimated CO₂.

Where is Argentina located?

Argentina is in Argentina at approximately -35.44682, -65.17536.

Built from open public data; no personal information. Operate this site? Request a correction or removal.