Home / United States / Food & beverage plants / Akutan Seafood Processing Facility

Akutan Seafood Processing Facility

Food & Beverage in United States. Approximate location 54.13219, -165.78689.

Food & BeverageUnited StatesCO₂ estimate (modelled)

Akutan Seafood Processing Facility is a food & beverage plant in United States. Its listed capacity is 564,725,044 USD. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency. By capacity it ranks #143 among 391 food & beverage plants in United States. It emits about 46,018 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 11k passenger cars.

46,018t CO₂e / yr (Climate TRACE)
#1034CO₂ rank in United States

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38482804.

Data status

Known source data

FacilityAkutan Seafood Processing Facility Climate TRACE
CountryUnited States Climate TRACE
Coordinates54.13219, -165.78689 Climate TRACE
Sector / subsectorfood-beverage-tobacco Climate TRACE
Reported capacity564,725,044 USD Climate TRACE
EPA parent companyTRIDENT SEAFOODS CORP US EPA GHGRP
EPA NAICS311710 US EPA GHGRP
TRI facility recordTRIDENT SEAFOODS CORP AKUTAN SHORE PLANT US EPA TRI
TRI parent companyTRIDENT SEAFOODS CORP US EPA TRI
TRI NAICS311710 US EPA TRI
TRI reported chemicalsEthylene glycol, Naphthalene US EPA TRI
TRI on-site releases171,275 lb/yr US EPA TRI
Modelled CO₂e46,018 t/yr Climate TRACE

Calculated from the dataset

United States rank#1034 of 1910 · top 54.1% calculated
Global food-beverage-tobacco rank#255 of 560 · top 45.5% calculated
Climate contextderived from coordinates calculated

Not available

Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

In context: how this facility compares

At 564,725,044 USD, Akutan Seafood Processing Facility is around the median food & beverage plant in United States (452,469,926 USD). Subsector: food-beverage-tobacco. As food & beverage plant, it requires high process heat (typically 80–200°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 46,018 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

11kcars driven for a year
6.0khomes' annual energy use
767ktree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 46k t CO₂e/yr (Scope 1), Akutan Seafood Processing Facility carries no domestic carbon price; food & beverage plants are not a CBAM-covered good, so there is no border-carbon liability. At the EU ETS reference price (€75/t) the emissions carry an indicative carbon value of €3.5M/yr. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈920 t–2k t/yr, worth €69k€173k, with payback up to 2 years. No domestic carbon price — but cement, steel, aluminium, fertilizer and hydrogen exported to the EU face CBAM at €75/t (rising to 100% by 2034).

46k t CO₂e / yrScope 1 emissions
€3.5M/yrindicative carbon value (not a CBAM liability)
920 t–2k t/yr ≈ €69k€173kDecarbonization potential

Carbon price: EU CBAM €75/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Parent company

Trident Seafoods Corp US EPA GHGRP
Parent company per US EPA GHGRP; the operator itself is not stated in the source dataset.

Local climate

Akutan Seafood Processing Facility sits in a tundra climate zone (Köppen ET), at 54.1°N in the northern hemisphere.

~-5°Ctypical annual mean
~6°Ctypical warm-season
Tundra: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a corrosive environment (estimated ISO 9223 class C4 — High), with marine corrosion the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
25/100environmental-severity index
11.5°Cseasonal temperature swing
13 kmdistance to coast
HighCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1466 W/m² to ambient — roughly 1.13× the loss at a 20 °C reference; removable insulation recovers about 1393 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

Nearby industrial sites

Location

Coordinates 54.13219, -165.78689. View on OpenStreetMap.

Heat loss & insulation profile

For a food & beverage plant, the main modular-insulation targets are cookers & kettles, pasteurisers, CIP hot-water sets, dryers, steam lines, tanks, valves. Typical hot-surface ranges used for screening: 70–200 °C.

very wide by site size; many bare low-temp surfaces (CIP, steam, pasteurisation) - often toward upper end.

Indicative recoverable energy

A first-pass insulation screen suggests about 2,100 MWh/year of recoverable heat-loss reduction and about 420 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

United States: funding & obligation

Funding. Investment tax credit up to 30% of qualified investment incl. industrial decarbonization; open to small/medium/large manufacturers. official source · verified 2026
Status: ~$6B of $10B allocated Jan-2025; remaining capacity + IRA status under political review — verify before 'apply now'.

Obligation. None at federal level (voluntary). Some states have their own programs. (applies as a rule above the stated threshold — we do not hold this site's metered energy use). · verified 2026

Programme terms verified 2026-06-18; confirm the current open phase before applying. Eligibility depends on a site's energy use / headcount, which we do not hold — not a per-facility eligibility determination.

Frequently asked questions

What type of facility is Akutan Seafood Processing Facility?

Akutan Seafood Processing Facility is a food & beverage plant in United States. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency.

How much CO₂ does Akutan Seafood Processing Facility emit?

The page uses about 46,018 t CO₂e/year from the open dataset It ranks #1034 among facilities in United States by estimated CO₂.

Where is Akutan Seafood Processing Facility located?

Akutan Seafood Processing Facility is in United States at approximately 54.13219, -165.78689.

Built from open public data; no personal information. Operate this site? Request a correction or removal.