Home / Europe / Spain / Food & beverage plants / Roquette Laisa España

Roquette Laisa España

Food & Beverage in Spain. Approximate location 39.28612, -0.4243.

Food & BeverageSpainCO₂ reported

Roquette Laisa España is a food & beverage plant in Spain with a reported capacity of 2,189,709,177 USD. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency. By capacity it ranks #7 among 8 food & beverage plants in Spain. It emits about 108,933 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 25k passenger cars.

108,933t CO₂e / yr (Climate TRACE)
#70CO₂ rank in Spain

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38480776.

Data status

Known source data

FacilityRoquette Laisa España Climate TRACE
CountrySpain Climate TRACE
Coordinates39.28612, -0.4243 Climate TRACE
Sector / subsectorfood-beverage-tobacco Climate TRACE
Reported capacity2,189,709,177 USD Climate TRACE
Modelled CO₂e108,933 t/yr Climate TRACE
Measured CO₂ cross-check68,789 t/yr measured cross-check · EUTL 2023

Calculated from the dataset

Spain rank#70 of 91 · top 76.9% calculated
Global food-beverage-tobacco rank#112 of 560 · top 20.0% calculated
Climate contextderived from coordinates calculated

Not available

Owner / operatorNot available not in dataset
Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

At 2,189,709,177 USD, Roquette Laisa España is below the median food & beverage plant in Spain (5,689,150,947 USD). Subsector: food-beverage-tobacco. As food & beverage plant, it requires high process heat (typically 80–200°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 108,933 t CO₂e a year looks like

This facility's reported annual CO₂e in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

25kcars driven for a year
14khomes' annual energy use
1.8 milliontree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 109k t CO₂e/yr (Scope 1), Roquette Laisa España carries €8.7M/yr of carbon at the full EU ETS price (€79/t CO₂). Free allocation phases out to 2034 (Reg. (EU) 2023/956), so today's bill is lower and rising toward this full-price figure. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈2k t–5k t/yr, worth €173k€433k, with payback up to 2 years.

Measured CO₂: 69k t/yr — verified EUTL (reporting year 2023) (37% below the modelled estimate). Modelled estimate 109k t/yr (Climate TRACE), high-confidence match, cross-checked via the measured-vs-modelled dataset (n=711).

109k t CO₂e / yrScope 1 emissions
€8.7M/yrcarbon value · full EU ETS price
2k t–5k t/yr ≈ €173k€433kDecarbonization potential

Carbon price: EU ETS €79/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: measured (EUTL RY2023), cross-checked vs Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Capacity vs largest food & beverage plants in Spain

Nanta, S.A.U. Las Palas: 36,017,646,281 USD36.0BNanta, S.A…Uve, S.A. (Fab. Piensos): 22,920,320,361 USD22.9BUve, S.A. …Productos Florida: 10,846,223,028 USD10.8BProductos …Corsa Petfood (Cardona): 5,689,150,947 USD5.7BCorsa Petf…S.A.T. Nufri 1956: 3,172,008,621 USD3.2BS.A.T. Nuf…Azucarera De Jerez - Centro De Guadalete: 2,251,102,893 USD2.3BAzucarera …Roquette Laisa España: 2,189,709,177 USD2.2BRoquette L…Bunge Iberica: 2,107,850,890 USD2.1BBunge Iber…

Reported capacity (USD), Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0).

Local climate

Roquette Laisa España sits in a hot-summer Mediterranean climate zone (Köppen Csa), at 39.3°N in the northern hemisphere.

~17°Ctypical annual mean
~27°Ctypical warm-season
Hot-summer mediterranean: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a corrosive environment (estimated ISO 9223 class C4 — High), with marine corrosion the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
40/100environmental-severity index
16.8°Cseasonal temperature swing
15 kmdistance to coast
HighCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1350 W/m² to ambient — roughly 1.04× the loss at a 20 °C reference; removable insulation recovers about 1282 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby sites

The #7 largest of 8 food & beverage plants in Spain by reported capacity.

Nearby industrial sites

Location

Coordinates 39.28612, -0.4243. View on OpenStreetMap.

Heat loss & insulation profile

For a food & beverage plant, the main modular-insulation targets are cookers & kettles, pasteurisers, CIP hot-water sets, dryers, steam lines, tanks, valves. Typical hot-surface ranges used for screening: 70–200 °C °C.

very wide by site size; many bare low-temp surfaces (CIP, steam, pasteurisation) - often toward upper end.

Indicative recoverable energy

A first-pass insulation screen suggests about 4,600 MWh/year of recoverable heat-loss reduction and about 920 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

EU policy pressure on this sector

Obligation

This facility is inside the EU. For thermal equipment, insulation upgrades can support ETS exposure reduction and energy-efficiency compliance.

Sources: EU ETS, CBAM and national energy-efficiency schemes.

Frequently asked questions

What type of facility is Roquette Laisa España?

Roquette Laisa España is a food & beverage plant in Spain. Food & beverage plants use boilers, cookers, pasteurisers and dryers that run continuously; heat loss from uninsulated piping and vessels directly reduces throughput and efficiency.

What capacity is reported for Roquette Laisa España?

The open dataset reports 2,189,709,177 USD of capacity for Roquette Laisa España.

How much CO₂ does Roquette Laisa España emit?

The page uses about 108,933 t CO₂e/year from the open dataset It ranks #70 among facilities in Spain by reported CO₂.

Where is Roquette Laisa España located?

Roquette Laisa España is in Spain at approximately 39.28612, -0.4243.

Built from open public data; no personal information. Operate this site? Request a correction or removal.