Finnfjord

Metals Plant in Norway. Approximate location 69.2226, 18.08218.

Metals PlantNorwayCO₂ estimate (modelled)

Finnfjord is a non-ferrous metals plant in Norway. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points; losses from uninsulated transfers and holding vessels are significant. It emits about 284,000 t CO₂e a year from Climate TRACE, roughly comparable to the annual emissions of 66k passenger cars.

284,000t CO₂e / yr (Climate TRACE)
#19CO₂ rank in Norway

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-3673313.

Data status

Known source data

FacilityFinnfjord Climate TRACE
CountryNorway Climate TRACE
Coordinates69.2226, 18.08218 Climate TRACE
Sector / subsectorother-metals Climate TRACE
Modelled CO₂e284,000 t/yr Climate TRACE
Measured CO₂ cross-check284,044 t/yr measured cross-check · EUTL 2023

Calculated from the dataset

Norway rank#19 of 46 · top 41.3% calculated
Global other-metals rank#28 of 416 · top 6.7% calculated
Climate contextderived from coordinates calculated

Not available

Owner / operatorNot available not in dataset
Fuel typeNot available not in dataset
Thermal capacity (MW)Not available not in dataset

Source data, measured cross-checks and calculated values are kept separate. No confidence percentage is invented.

Similar facilities by modelled emissions

Same Climate TRACE subsector; closest non-placeholder modelled CO₂e values. Russia and Belarus excluded.

Operating power plants within 50 km

PowerAtlas operating assets, ordered by great-circle distance from published coordinates.

In context: how this facility compares

Subsector: other-metals. As non-ferrous metals plant, it requires high process heat (typically 400–1200°C) for its core industrial operations — heat that must be supplied by boilers, furnaces or direct combustion, and losses through uninsulated vessels and piping represent wasted fuel. Removable modular insulation can cut those losses by 80–96%, surface-cooling equipment to ≤45°C, with payback often under 2 years. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points; losses from uninsulated transfers and holding vessels are significant.

Capacity & CO₂-intensity comparison computed from Climate TRACE industrial facilities data; sector role based on engineering reference.

What 284,000 t CO₂e a year looks like

This facility's estimated annual CO₂e (Climate TRACE, modelled) in everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

66kcars driven for a year
37khomes' annual energy use
4.7 milliontree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Carbon cost, Scope 1 & decarbonization potential

At its reported 284k t CO₂e/yr (Scope 1), Finnfjord carries €22.6M/yr of carbon at the full EU ETS price (€79/t CO₂). Free allocation phases out to 2034 (Reg. (EU) 2023/956), so today's bill is lower and rising toward this full-price figure. The fastest decarbonization lever is energy efficiency: eliminating heat loss on hot equipment (removable insulation, steam & waste-heat recovery) typically cuts 2–5% of fuel-related CO₂ — here ≈6k t–14k t/yr, worth €451k€1.1M, with payback up to 2 years.

Measured CO₂: 284k t/yr — verified EUTL (reporting year 2023) (0% above the modelled estimate). Modelled estimate 284k t/yr (Climate TRACE), high-confidence match, cross-checked via the measured-vs-modelled dataset (n=711).

284k t CO₂e / yrScope 1 emissions
€22.6M/yrcarbon value · full EU ETS price
6k t–14k t/yr ≈ €451k€1.1MDecarbonization potential

Carbon price: EU ETS €79/t · EU ETS €79/t, July 2, 2026, refreshed live via Carbon Hub. CO₂: measured (EUTL RY2023), cross-checked vs Climate TRACE. Efficiency range: US DOE / ASTM C680 (method). Indicative carbon value, not the cash bill — free allocation applies; not compliance advice. Estimate the saving for this site →

Local climate

Finnfjord sits in a subarctic (boreal) climate zone (Köppen Dfc), at 69.2°N in the northern hemisphere.

~0°Ctypical annual mean
~14°Ctypical warm-season
Subarctic (boreal): very cold for most of the year

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

The local climate sets how fast unprotected steel, protective coatings and the insulation on hot process equipment degrade at this site. It sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
24/100environmental-severity index
19.9°Cseasonal temperature swing
59 kmdistance to coast
LowCUI risk tier

In this site’s local climate, a bare 150 °C surface sheds about 1495 W/m² to ambient — roughly 1.15× the loss at a 20 °C reference; removable insulation recovers about 1420 W/m² of that. Reference-surface calculation at a 150 °C surface from WorldClim climate normals (ASTM C680 / ISO 12241) — an indicative per-climate comparison, not a measurement of this site’s specific equipment. Open method dataset: DOI 10.5281/zenodo.20787408 (CC BY 4.0).

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

Location

Coordinates 69.2226, 18.08218. View on OpenStreetMap.

Heat loss & insulation profile

For a non-ferrous metals plant, the main modular-insulation targets are furnaces, ladles, heat-treatment ovens, ducting & valves. Typical hot-surface ranges used for screening: 150–1,000 °C.

Indicative recoverable energy

A first-pass insulation screen suggests about 3,000 MWh/year of recoverable heat-loss reduction and about 600 t CO₂e/year of avoided emissions. Screening estimate scaled from installed process-heat projects and surface-temperature reduction data.

See Inzonex Modular Insulation → Run the calculator →

Screening calculation from facility class, capacity and open emissions/energy context. Engineering survey required before procurement.

Safety & the no-regret first step

Start with a thermal survey of valves, flanges, doors and bends. Removable modular insulation keeps maintenance access open while lowering exposed-surface temperature and wasted heat.

External climate finance your country can access

For energy-efficiency projects around process heat, likely external funding channels include:

Sources: country climate-finance facilities and public development-bank programmes.

Frequently asked questions

What type of facility is Finnfjord?

Finnfjord is a non-ferrous metals plant in Norway. Non-ferrous metals plants melt, refine and cast metals in furnaces and crucibles above their melting points; losses from uninsulated transfers and holding vessels are significant.

How much CO₂ does Finnfjord emit?

The page uses about 284,000 t CO₂e/year from the open dataset It ranks #19 among facilities in Norway by estimated CO₂.

Where is Finnfjord located?

Finnfjord is in Norway at approximately 69.2226, 18.08218.

Built from open public data; no personal information. Operate this site? Request a correction or removal.