Home / Europe / Portugal / Lime plants / Calcidrata - Indústrias De Cal, S. A. (Ci)

Calcidrata - Indústrias De Cal, S. A. (Ci)

Lime Plant in Portugal. Approximate location 39.4545, -8.8466.

Lime PlantPortugalCO₂ reported

Calcidrata - Indústrias De Cal, S. A. (Ci) is a lime plant in Portugal with a reported capacity of 401,965 t of lime. It calcines limestone into quicklime in high-temperature kilns. By capacity it ranks #5 of 5 lime plants tracked in Portugal. It emits about 264,680 tonnes of CO₂e per year (Climate TRACE) — roughly the tailpipe emissions of 61,697 cars.

401,965t of lime
264,680t CO₂e / yr (Climate TRACE)
#21CO₂ rank in Portugal
0.66t CO₂ per capacity unit

Facility data: Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0), id ct-38467719.

W kontekście: jak ta instalacja się porównuje

Przy 401,965 t of lime, Calcidrata - Indústrias De Cal, S. A. (Ci) jest poniżej medianę lime plant w Portugal (702,065 t of lime). Podsektor: lime. Jako lime plant, wymaga intensywnego ciepła procesowego (typowo 600–900°C) do swoich głównych operacji przemysłowych — ciepła, które musi być dostarczane przez kotły, piece lub spalanie bezpośrednie, a straty przez nieisolowane zbiorniki i rury stanowią zmarnowane paliwo. Modułowa izolacja demontowalna może zmniejszyć te straty o 80–96%, chłodząc powierzchnie do ≤45°C, z zwrotem inwestycji często poniżej 2 lat. Huty wapienne kalcynują wapień w gorących piecach w temperaturze 800–900°C, a gorący wapień żywy musi być obsługiwany w izolowanych zbiornikach, aby uniknąć reaktywności z wilgocią.

Porównanie pojemności i intensywności CO₂ obliczane na podstawie danych instalacji przemysłowych Climate TRACE; rola sektora oparta na odniesieniau inżynierskim.

What 264,680 t CO₂e a year looks like

This facility's reported annual CO₂e in the everyday equivalents from the US EPA Greenhouse Gas Equivalencies calculator:

61,697cars driven for a year
34,517homes' annual energy use
4,411,333tree seedlings grown 10 years

Equivalencies: US EPA Greenhouse Gas Equivalencies. Emissions: Climate TRACE.

Capacity vs largest lime plants in Portugal

Fábrica Maceira-Liz (Ci): 1,173,670 t of lime1.2MFábrica Ma…Centro De Produção De Loulé (Ci): 787,534 t of lime788kCentro De …Fábrica Cibra-Pataias (Ci): 702,065 t of lime702kFábrica Ci…Lusical, Companhia Lusitana De Cal Sa (Ci): 538,759 t of lime539kLusical, C…Calcidrata - Indústrias De Cal, S. A. (Ci): 401,965 t of lime402kCalcidrata…

Reported capacity (t of lime), Climate TRACE v6 (asset-level capacity & CO₂e, CC BY 4.0).

Local climate

Calcidrata - Indústrias De Cal, S. A. (Ci) sits in a hot-summer Mediterranean climate zone (Köppen Csa), at 39.5°N in the northern hemisphere.

~17°Ctypical annual mean
~27°Ctypical warm-season
Hot-summer mediterranean: four distinct seasons — cold winters and warm summers

Köppen zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

How it compares & nearby sites

The #5 largest of 5 lime plants in Portugal by reported capacity.

Nearby industrial sites

Location

Coordinates 39.4545, -8.8466. View on OpenStreetMap.

Heat loss & insulation profile

A lime plant like this runs hot equipment that sheds heat continuously: kiln, preheater, hot-gas ducting, valves & dampers (surface/process temperatures around 200–900 °C). These surfaces lose energy to the air year-round; removable modular insulation cuts that loss, brings outer surfaces to ≤45 °C, and unclips for inspection.

calcination-heavy like cement; fuel side only.

Indicative recoverable energy

On an already-insulated site (pipes & valves in cladding / jackets), closing the remaining gaps, flanges and damaged sections and switching to removable covers indicatively recovers about 8,900 MWh/yr (≈ 3,000 t CO₂/yr) — scaled to this site's reported CO₂ within its sector. Bare or damaged surfaces recover several times more.

See Inzonex insulation → Estimate your site →

Indicative, not a measurement. Conservative floor for an already-insulated plant; a TIPCHECK on-site audit gives a measured figure. Industry context: EiiF TIPCHECK — industrial insulation can save ~14 Mtoe/yr in EU, payback typically <2 years.

Safety & the no-regret first step

Bare hot surfaces here exceed the touch-safe limit (EN ISO 13732-1); insulation to ≤45 °C is a worker-safety and compliance win. And before electrification, fuel-switching or CCS, eliminating surface heat loss is the cheapest, fastest, lowest-risk step — audit the bare spots first, rip-and-replace later.

EU: funding & obligation

Obligation. Under the EU Energy Efficiency Directive (Art. 8), large undertakings (>250 staff or >€50M turnover / >€43M balance) must run an energy audit every 4 years or operate a certified energy management system (ISO 50001).

Funding. National energy-efficiency grants and white-certificate schemes typically apply — check the local programme.

EED Article 8, transposed nationally. Confirm current national terms.

Frequently asked questions

What type of facility is Calcidrata - Indústrias De Cal, S. A. (Ci)?

Calcidrata - Indústrias De Cal, S. A. (Ci) is a lime plant in Portugal. It calcines limestone into quicklime in high-temperature kilns.

What is the capacity of Calcidrata - Indústrias De Cal, S. A. (Ci)?

Calcidrata - Indústrias De Cal, S. A. (Ci) has a reported capacity of 401,965 t of lime.

How much CO₂ does Calcidrata - Indústrias De Cal, S. A. (Ci) emit?

Calcidrata - Indústrias De Cal, S. A. (Ci) emits about 264,680 tonnes of CO₂e per year (Climate TRACE) — roughly the tailpipe emissions of 61,697 cars. That ranks #21 among tracked facilities in Portugal.

Where is Calcidrata - Indústrias De Cal, S. A. (Ci) located?

Calcidrata - Indústrias De Cal, S. A. (Ci) is in Portugal, near coordinates 39.4545, -8.8466.

Built from open public data; no personal information. Operate this site? Request a correction or removal.