InzonexHRSG thickness
Upper HP reference · 460 °C

125 mm insulation: heat loss and outside surface

Upper HP support flange with metal bellows. Oman reference weather, measured component geometry, outdoor convection and radiation.

Calculated result

Bare heat loss47.174 kW
Physics-model residual0.474 kW
Public planning residual1.887 kW · 96% cap
Heat retained shown publicly45.287 kW
Outside surface38.2 °C · target met
Calculation inputs: 460 °C process, 27.7 °C ambient, 3.1 m/s wind, 125 mm Wired Mat, measured support-flange and corrugated-bellows geometry. The thickness graph uses the physics-model residual; the public savings total keeps the 96% reduction cap.

What the result means

For the Upper HP support flange with metal bellows and the stated Oman weather inputs, the model gives 38.2 °C outside surface and meets the ≤45 °C target.

Residual heat loss and outside-surface temperature fall. The improvement becomes smaller at each additional thickness step, so clearance, mass and access still need engineering review.

Open this case in Your savings →
Is 125 mm enough at 460 °C?

For the Upper HP support flange with metal bellows and the stated Oman weather inputs, the model gives 38.2 °C outside surface and meets the ≤45 °C target.

What changes when thickness increases?

Residual heat loss and outside-surface temperature fall. The improvement becomes smaller at each additional thickness step, so clearance, mass and access still need engineering review.

Are these thermography measurements?

No. These values are calculated from the measured geometry and operating inputs. The separate survey thermogram is evidence of the exposed hot component, not the insulated prediction.