InzonexHRSG unit
Upper IP line

Metal bellows

A separate IP-line calculation with its own reference duty and metal-bellows geometry.

What is included

This selection does not inherit the HP reference temperature. The user can adjust temperature and site count from the IP starting point.

Reference temperature180 °C
Starting quantity1 · enter your site count
Bare heat loss4.672 kW
With insulation0.187 kW
Heat retained4.485 kW
Reduction96%
Outside surface34.8 °C · target met
Temperature and quantity are editable. Energy rate, installed cost and payback remain blank until entered by the operator.

Why removable insulation matters

The module can be removed to expose the metal component and fasteners, then returned to the same position. This supports inspection without destroying and rebuilding the insulation each time.

Equipment-life boundary

Lower thermal exposure and repeatable inspection can support equipment care. A fixed life-extension figure needs component material, stress, cycling, drainage and inspection history.

Open this area in Your savings →