  "dataset": "inzonex-industrial-insulation-conductivity-source-rows",
  "version": "2026-08-30.1",
  "row_count": 122,
  "coverage": "Existing source catalogue plus PAROC Pro Lamella Mat AluCoat; local candidate",
  "license": "CC BY 4.0 for Inzonex compilation and metadata; manufacturer facts remain attributed",
  "points": [
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.040",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.046",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.054",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.064",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 250,
      "conductivity_W_mK": "0.077",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.092",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 960 with WR-Tech",
      "density_kg_m3": 100,
      "density_qualifier": ">=",
      "source_temp_degC": 350,
      "conductivity_W_mK": "0.112",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "PDS 017/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-960-en-um.pdf",
      "page_table_location": "Page 1, Properties / Thermal conductivity",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.041",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.046",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.053",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.061",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 250,
      "conductivity_W_mK": "0.071",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.083",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 350,
      "conductivity_W_mK": "0.096",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.111",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 500,
      "conductivity_W_mK": "0.146",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 600,
      "conductivity_W_mK": "0.186",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox WM 960 ES",
      "density_kg_m3": 100,
      "density_qualifier": "Nominal",
      "source_temp_degC": 660,
      "conductivity_W_mK": "0.213",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Manufacturer table label T (C); document does not explicitly say mean temperature",
      "form_geometry": "Wired mat",
      "max_service_degC": 660,
      "max_service_meaning": "Maximum service temperature under EN 14706; not a conductivity-table endpoint",
      "source_title_version_date": "PRODUCT DATA SHEET INT - PEN-01-2-002, issued 2026-07-17",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-wm-960-en.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "ES-designated product variant; sales geography not stated",
      "availability_caveat": "Confirm regional availability and exact ES variant; do not merge with older WM 960 curves",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.040",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.046",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.053",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.062",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 250,
      "conductivity_W_mK": "0.073",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.085",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "ROCKWOOL Technical Insulation",
      "product_grade": "ProRox PS 970 with WR-Tech",
      "density_kg_m3": 140,
      "density_qualifier": "Nominal",
      "source_temp_degC": 350,
      "conductivity_W_mK": "0.099",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 680,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity documented to 350 C mean",
      "source_title_version_date": "PRODUCT DATA SHEET ENG - PDS 020/EN, issued 2018-04-01",
      "source_url": "https://rti.rockwool.com/siteassets/tools--documentation/products-industrial/product-data-sheets/english/rw-ti-pds-prorox-ps-970-en-UM.pdf",
      "page_table_location": "Properties / thermal conductivity at mean temperature",
      "geography": "EN properties apply to European production facilities",
      "availability_caveat": "Current manufacturer page still links the 2018 sheet; confirm current regional stock and dimensions",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.044",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.054",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.067",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.083",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 250,
      "conductivity_W_mK": "0.104",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.130",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.202",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "Knauf Insulation",
      "product_grade": "Power-teK LM 450 ALU",
      "density_kg_m3": 40,
      "density_qualifier": "Approximate",
      "source_temp_degC": 450,
      "conductivity_W_mK": "0.250",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667",
      "temperature_basis": "Temperature-dependent manufacturer table labelled theta (C); document does not explicitly say mean temperature",
      "form_geometry": "Lamella mat",
      "max_service_degC": 450,
      "max_service_meaning": "Maximum service temperature under EN ISO 18097; aluminium facing <=80 C",
      "source_title_version_date": "Technical Data Sheet Power-teK LM 450 ALU, valid from 2024-11",
      "source_url": "https://pim.knaufinsulation.com/files/download/download_67644de70197e.pdf",
      "page_table_location": "Thermal conductivity depending on temperature, theta (C)",
      "geography": "Global Technical Solutions sheet; manufacturer in Croatia",
      "availability_caveat": "Standard thickness 30-120 mm; regional stock not proven and aluminium facing is limited to 80 C",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 10,
      "conductivity_W_mK": "0.033",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.037",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.045",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.063",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.088",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.122",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "ULTIMATE mineral wool",
      "material_slug": "ultimate-mineral-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "U TECH Wired Mat MT 4.0 Alu1/V1/X",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 500,
      "conductivity_W_mK": "0.163",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 12667 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Wired mat",
      "max_service_degC": 560,
      "max_service_meaning": "Maximum service temperature 560 C under EN 14706; separate ASTM limit 650 C is not the EN table endpoint",
      "source_title_version_date": "U TECH Wired Mat MT 4.0 Alu1/V1/X TDS, imprint 2024-03",
      "source_url": "https://www.isover-technical-insulation.com/documents/technical-datasheets/tds-u-tech-wired-mat-mt-4.0-alu1v1x.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation sheet",
      "availability_caveat": "Standard 600 mm width and 30-120 mm thickness require minimum quantities; regional stock not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 10,
      "conductivity_W_mK": "0.033",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.036",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.043",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.062",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.092",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "TECH Pipe Section MT 4.2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in TDS",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.130",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "ISO 8497 / EN ISO 13787",
      "temperature_basis": "Manufacturer table label T (C); EN ISO 13787 declared-value treatment",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature under EN 14707; conductivity table ends at 400 C",
      "source_title_version_date": "TDS TECH Pipe Section MT 4.2, imprint 2022-11",
      "source_url": "https://www.isover-technical-insulation.com/documents/pipe-sections/tds-tech-pipe-section-mt-4.2.pdf",
      "page_table_location": "Thermal conductivity table, T (C)",
      "geography": "Global ISOVER Technical Insulation product",
      "availability_caveat": "Current manufacturer page links the 2022 sheet; dimensions have minimum-order caveats and regional stock is not proven",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 10,
      "conductivity_W_mK": "0.033",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.036",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.043",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.062",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.092",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Glass wool",
      "material_slug": "glass-wool",
      "manufacturer": "Saint-Gobain ISOVER",
      "product_grade": "CLIMPIPE Section Alu2",
      "density_kg_m3": null,
      "density_qualifier": "Not stated in current PDS",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.130",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN 14303 declaration",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 500,
      "max_service_meaning": "Continuous service 5 to 500 C; aluminium facing <=80 C",
      "source_title_version_date": "Isover CLIMPIPE Section Alu2 PDS, 2026-07-28",
      "source_url": "https://www.isover.co.uk/documents/product-datasheet/isover-pds-isover-climpipe-section-alu2.pdf",
      "page_table_location": "Page 2, Product Specification / declared conductivity table",
      "geography": "UK PDS; manufactured in Sweden",
      "availability_caveat": "EPD conversion range is not proof of current stock; below-dew-point use requires a continuous vapour barrier",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "AES blanket",
      "material_slug": "ceramic-fiber",
      "manufacturer": "Morgan Thermal Ceramics",
      "product_grade": "Superwool Plus Blanket, 128 kg/m3",
      "density_kg_m3": 128,
      "density_qualifier": "Nominal",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.050",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C201",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Blanket",
      "max_service_degC": 1050,
      "max_service_meaning": "Continuous use; 1200 C classification temperature",
      "source_title_version_date": "Superwool Plus Blankets, checked 2025-04-18",
      "source_url": "https://www.morganthermalceramics.com/media/l52g3r3j/superwool-plus-blankets_eng.pdf",
      "page_table_location": "Thermal conductivity, 128 kg/m3 column",
      "geography": "Global product statement; availability varies by region",
      "availability_caveat": "Density and thickness availability vary by region; confirm the 128 kg/m3 grade and supplied thickness",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "AES blanket",
      "material_slug": "ceramic-fiber",
      "manufacturer": "Morgan Thermal Ceramics",
      "product_grade": "Superwool Plus Blanket, 128 kg/m3",
      "density_kg_m3": 128,
      "density_qualifier": "Nominal",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.080",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C201",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Blanket",
      "max_service_degC": 1050,
      "max_service_meaning": "Continuous use; 1200 C classification temperature",
      "source_title_version_date": "Superwool Plus Blankets, checked 2025-04-18",
      "source_url": "https://www.morganthermalceramics.com/media/l52g3r3j/superwool-plus-blankets_eng.pdf",
      "page_table_location": "Thermal conductivity, 128 kg/m3 column",
      "geography": "Global product statement; availability varies by region",
      "availability_caveat": "Density and thickness availability vary by region; confirm the 128 kg/m3 grade and supplied thickness",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "AES blanket",
      "material_slug": "ceramic-fiber",
      "manufacturer": "Morgan Thermal Ceramics",
      "product_grade": "Superwool Plus Blanket, 128 kg/m3",
      "density_kg_m3": 128,
      "density_qualifier": "Nominal",
      "source_temp_degC": 600,
      "conductivity_W_mK": "0.120",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C201",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Blanket",
      "max_service_degC": 1050,
      "max_service_meaning": "Continuous use; 1200 C classification temperature",
      "source_title_version_date": "Superwool Plus Blankets, checked 2025-04-18",
      "source_url": "https://www.morganthermalceramics.com/media/l52g3r3j/superwool-plus-blankets_eng.pdf",
      "page_table_location": "Thermal conductivity, 128 kg/m3 column",
      "geography": "Global product statement; availability varies by region",
      "availability_caveat": "Density and thickness availability vary by region; confirm the 128 kg/m3 grade and supplied thickness",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "AES blanket",
      "material_slug": "ceramic-fiber",
      "manufacturer": "Morgan Thermal Ceramics",
      "product_grade": "Superwool Plus Blanket, 128 kg/m3",
      "density_kg_m3": 128,
      "density_qualifier": "Nominal",
      "source_temp_degC": 800,
      "conductivity_W_mK": "0.180",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C201",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Blanket",
      "max_service_degC": 1050,
      "max_service_meaning": "Continuous use; 1200 C classification temperature",
      "source_title_version_date": "Superwool Plus Blankets, checked 2025-04-18",
      "source_url": "https://www.morganthermalceramics.com/media/l52g3r3j/superwool-plus-blankets_eng.pdf",
      "page_table_location": "Thermal conductivity, 128 kg/m3 column",
      "geography": "Global product statement; availability varies by region",
      "availability_caveat": "Density and thickness availability vary by region; confirm the 128 kg/m3 grade and supplied thickness",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "AES blanket",
      "material_slug": "ceramic-fiber",
      "manufacturer": "Morgan Thermal Ceramics",
      "product_grade": "Superwool Plus Blanket, 128 kg/m3",
      "density_kg_m3": 128,
      "density_qualifier": "Nominal",
      "source_temp_degC": 1000,
      "conductivity_W_mK": "0.250",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C201",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Blanket",
      "max_service_degC": 1050,
      "max_service_meaning": "Continuous use; 1200 C classification temperature",
      "source_title_version_date": "Superwool Plus Blankets, checked 2025-04-18",
      "source_url": "https://www.morganthermalceramics.com/media/l52g3r3j/superwool-plus-blankets_eng.pdf",
      "page_table_location": "Thermal conductivity, 128 kg/m3 column",
      "geography": "Global product statement; availability varies by region",
      "availability_caveat": "Density and thickness availability vary by region; confirm the 128 kg/m3 grade and supplied thickness",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 0,
      "conductivity_W_mK": "0.020",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.023",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.028",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.035",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.046",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 500,
      "conductivity_W_mK": "0.064",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Aerogel",
      "material_slug": "aerogel",
      "manufacturer": "Aspen Aerogels",
      "product_grade": "Pyrogel XTE",
      "density_kg_m3": 200,
      "density_qualifier": "Nominal",
      "source_temp_degC": 600,
      "conductivity_W_mK": "0.089",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C177 at 2 psi",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flexible blanket",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum use temperature",
      "source_title_version_date": "Pyrogel XTE product data sheet, Rev 4.2, 2023",
      "source_url": "https://www.aerogel.com/wp-content/uploads/2021/06/Pyrogel-XTE-Datasheet-English-v4.2.pdf",
      "page_table_location": "Page 1, Thermal conductivity table",
      "geography": "US manufacturer; exact sales geography not stated in PDS",
      "availability_caveat": "Nominal blanket thicknesses are 5 and 10 mm; entered calculator thickness does not imply a supplied single layer",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 38,
      "conductivity_W_mK": "0.050",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 93,
      "conductivity_W_mK": "0.056",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 149,
      "conductivity_W_mK": "0.063",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 204,
      "conductivity_W_mK": "0.070",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 260,
      "conductivity_W_mK": "0.078",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 316,
      "conductivity_W_mK": "0.085",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 371,
      "conductivity_W_mK": "0.093",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 38,
      "conductivity_W_mK": "0.051",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 93,
      "conductivity_W_mK": "0.054",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 149,
      "conductivity_W_mK": "0.057",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 204,
      "conductivity_W_mK": "0.062",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 260,
      "conductivity_W_mK": "0.067",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 316,
      "conductivity_W_mK": "0.073",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Calcium silicate",
      "material_slug": "calcium-silicate",
      "manufacturer": "Johns Manville",
      "product_grade": "Thermo-12 Gold",
      "density_kg_m3": 230,
      "density_qualifier": ">=",
      "source_temp_degC": 371,
      "conductivity_W_mK": "0.081",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "IND-300 Thermo-12 Gold product data sheet",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/calcium-silicate/thermo-12-gold/IND-300-Thermo-12-Gold.pdf",
      "page_table_location": "Thermal conductivity table, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 38,
      "conductivity_W_mK": "0.059",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 93,
      "conductivity_W_mK": "0.069",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 149,
      "conductivity_W_mK": "0.079",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 204,
      "conductivity_W_mK": "0.088",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 260,
      "conductivity_W_mK": "0.097",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 316,
      "conductivity_W_mK": "0.105",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 371,
      "conductivity_W_mK": "0.113",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C335",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Pipe section",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C335 (Pipe)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 38,
      "conductivity_W_mK": "0.063",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 93,
      "conductivity_W_mK": "0.069",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 149,
      "conductivity_W_mK": "0.074",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 204,
      "conductivity_W_mK": "0.080",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 260,
      "conductivity_W_mK": "0.087",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 316,
      "conductivity_W_mK": "0.093",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Expanded perlite",
      "material_slug": "expanded-perlite",
      "manufacturer": "Johns Manville",
      "product_grade": "Sproule WR-1200",
      "density_kg_m3": 240,
      "density_qualifier": "<",
      "source_temp_degC": 371,
      "conductivity_W_mK": "0.100",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ASTM C518",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Flat specimen",
      "max_service_degC": 650,
      "max_service_meaning": "Maximum service temperature",
      "source_title_version_date": "Sproule WR-1200 data sheet, checked 2025-04-10",
      "source_url": "https://www.jm.com/content/dam/jm/global/en/industrial-insulation/perlite/sproule-wr-1200/JM_IND_Sproule_WR_1200_DS.pdf",
      "page_table_location": "Page 1, ASTM C518 (Flat)",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": -180,
      "conductivity_W_mK": "0.020",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": -150,
      "conductivity_W_mK": "0.022",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": -120,
      "conductivity_W_mK": "0.025",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": -80,
      "conductivity_W_mK": "0.029",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": -40,
      "conductivity_W_mK": "0.034",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 0,
      "conductivity_W_mK": "0.040",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 40,
      "conductivity_W_mK": "0.046",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 80,
      "conductivity_W_mK": "0.054",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 120,
      "conductivity_W_mK": "0.061",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 180,
      "conductivity_W_mK": "0.075",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 240,
      "conductivity_W_mK": "0.090",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Cellular glass",
      "material_slug": "cellular-glass",
      "manufacturer": "Owens Corning",
      "product_grade": "FOAMGLAS ONE",
      "density_kg_m3": 115,
      "density_qualifier": "\u00b115%",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.107",
      "value_basis": "MANUFACTURER_DECLARED_TABLE",
      "source_expression": "",
      "test_method": "EN ISO 13787",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Block",
      "max_service_degC": 430,
      "max_service_meaning": "Maximum service temperature; minimum -265 C",
      "source_title_version_date": "FOAMGLAS ONE product data sheet, November 2020",
      "source_url": "https://www.foamglas.com/-/media/project/foamglas/public/shared/files/foamglas-i/one/eu/pds/pds-foamglas-one-eu-en.pdf",
      "page_table_location": "EN ISO 13787 selected mean-temperature declared values",
      "geography": "European EN 14305 product declaration",
      "availability_caveat": "Current table applies to the block product; do not silently transfer the superseded slab/half-slab table",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_DECLARATION_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Microporous",
      "material_slug": "microporous",
      "manufacturer": "Promat",
      "product_grade": "PROMALIGHT 1000R",
      "density_kg_m3": 320,
      "density_qualifier": "Nominal",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.022",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ISO 8302 / ASTM C177",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Board",
      "max_service_degC": 1000,
      "max_service_meaning": "Classification temperature",
      "source_title_version_date": "PROMALIGHT technical data sheet, 2018-04",
      "source_url": "https://media.promat.com/pi508586/original/590778644/promalight_tds_en.pdf",
      "page_table_location": "Page 1, Thermal conductivity, -1000R column",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Microporous",
      "material_slug": "microporous",
      "manufacturer": "Promat",
      "product_grade": "PROMALIGHT 1000R",
      "density_kg_m3": 320,
      "density_qualifier": "Nominal",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.024",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ISO 8302 / ASTM C177",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Board",
      "max_service_degC": 1000,
      "max_service_meaning": "Classification temperature",
      "source_title_version_date": "PROMALIGHT technical data sheet, 2018-04",
      "source_url": "https://media.promat.com/pi508586/original/590778644/promalight_tds_en.pdf",
      "page_table_location": "Page 1, Thermal conductivity, -1000R column",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Microporous",
      "material_slug": "microporous",
      "manufacturer": "Promat",
      "product_grade": "PROMALIGHT 1000R",
      "density_kg_m3": 320,
      "density_qualifier": "Nominal",
      "source_temp_degC": 600,
      "conductivity_W_mK": "0.029",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ISO 8302 / ASTM C177",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Board",
      "max_service_degC": 1000,
      "max_service_meaning": "Classification temperature",
      "source_title_version_date": "PROMALIGHT technical data sheet, 2018-04",
      "source_url": "https://media.promat.com/pi508586/original/590778644/promalight_tds_en.pdf",
      "page_table_location": "Page 1, Thermal conductivity, -1000R column",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Microporous",
      "material_slug": "microporous",
      "manufacturer": "Promat",
      "product_grade": "PROMALIGHT 1000R",
      "density_kg_m3": 320,
      "density_qualifier": "Nominal",
      "source_temp_degC": 800,
      "conductivity_W_mK": "0.034",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_expression": "",
      "test_method": "ISO 8302 / ASTM C177",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Board",
      "max_service_degC": 1000,
      "max_service_meaning": "Classification temperature",
      "source_title_version_date": "PROMALIGHT technical data sheet, 2018-04",
      "source_url": "https://media.promat.com/pi508586/original/590778644/promalight_tds_en.pdf",
      "page_table_location": "Page 1, Thermal conductivity, -1000R column",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": -50,
      "conductivity_W_mK": "0.03579",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": 0,
      "conductivity_W_mK": "0.03764",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": 40,
      "conductivity_W_mK": "0.042",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.04349",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.05334",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Elastomeric foam",
      "material_slug": "elastomeric",
      "manufacturer": "Armacell",
      "product_grade": "HT/ArmaFlex tubes",
      "density_kg_m3": null,
      "density_qualifier": "Not stated on technical-specification page",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.06719",
      "value_basis": "CALCULATED_FROM_DECLARED_FORMULA",
      "source_expression": "lambda=[36.92+0.125*T+0.0008*(T-30)^2]/1000",
      "test_method": "EN ISO 13787 / EN 12667 / EN ISO 8497",
      "temperature_basis": "Mean temperature",
      "form_geometry": "Closed-cell EPDM elastomeric tube",
      "max_service_degC": 150,
      "max_service_meaning": "Maximum recommended service temperature",
      "source_title_version_date": "HT/ArmaFlex technical specifications, checked 2026-08-29",
      "source_url": "https://www.armacell.com/en-GB/product/technical-specs/htarmaflex",
      "page_table_location": "Thermal conductivity, tubes formula",
      "geography": "Not stated",
      "availability_caveat": "Confirm current availability",
      "source_access_status": "Primary source checked",
      "checked_date": "2026-08-29",
      "verification_status": "PRIMARY_FORMULA_CALCULATED",
      "publication_status": "PUBLISHABLE"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 10,
      "conductivity_W_mK": "0.039"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 50,
      "conductivity_W_mK": "0.045"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 100,
      "conductivity_W_mK": "0.055"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 150,
      "conductivity_W_mK": "0.066"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 200,
      "conductivity_W_mK": "0.082"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 300,
      "conductivity_W_mK": "0.125"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 400,
      "conductivity_W_mK": "0.175"
    },
    {
      "material_class": "Stone wool",
      "material_slug": "stone-wool",
      "manufacturer": "PAROC",
      "product_grade": "Pro Lamella Mat AluCoat",
      "form_geometry": "Lamella mat",
      "density_kg_m3": 50,
      "test_method": "EN 12667",
      "source_title_version_date": "Product datasheet, updated 2024-06-05",
      "source_url": "https://www.paroc.com/en-us/documents/uploads/paroc-pro-lamella-mat-alucoat.pdf",
      "page_table_location": "Page 2, Thermal properties; page 1, facing and dimensional stability",
      "temperature_basis": "Mean temperature",
      "temperature_basis_evidence": "EN 12667 declared conductivity interpreted at material mean temperature, following PAROC thickness-guide note 5. The product sheet labels lambda at each temperature, not process-surface temperature.",
      "temperature_basis_source": "https://www.paroc.com/en/documents/uploads/guide-to-paroc-stone-wool-thicknesses",
      "max_service_degC": 500,
      "max_service_meaning": "Maximum service temperature for dimensional stability, EN 14706",
      "max_facing_degC": 80,
      "application_scope": "Air ducts, ventilation ducts and equipment. Thermal screening does not establish suitability for every geometry or duty.",
      "geography": "International use (general information)",
      "checked_date": "2026-08-30",
      "source_access_status": "Primary PDF HTTP 200; all conductivity rows read from page 2",
      "verification_status": "PRIMARY_SOURCE_CHECKED",
      "publication_status": "LOCAL_CANDIDATE",
      "value_basis": "PUBLISHED_TABLE_POINT",
      "source_temp_degC": 500,
      "conductivity_W_mK": "0.235"
    }
  ]
}